Hunter Industries - The Irrigation Innovators
I-40 Nozzle Performance Data
I-40 Nozzle Performance Data

Pressure Radius Flow Precip in/hr
Nozzle PSI ft. GPM
40 40
50
60
45'
46'
46'
7.0
8.0
8.5
0.67
0.73
0.77
0.77
0.84
0.89
41 50
60
70
80
50'
51'
52'
53'
10.2
11.1
12.1
13.0
0.79
0.82
0.86
0.89
0.91
0.95
0.99
1.03
42 50
60
70
80
51'
53'
55'
56'
11.0
12.3
13.1
13.9
0.81
0.84
0.83
0.85
0.94
0.97
0.96
0.99
43 50
60
70
80
56'
57'
59'
61'
13.5
15.1
16.1
17.5
0.83
0.89
0.89
0.91
0.96
1.03
1.03
1.05
44 60
70
80
90
63'
65'
66'
67'
20.0
21.8
23.4
24.9
0.97
0.99
1.03
1.07
1.12
1.15
1.19
1.23
45 60
70
80
90
66'
68'
69'
70'
22.7
24.7
26.4
28.2
1.00
1.03
1.07
1.11
1.16
1.19
1.23
1.28

I-42 Nozzle Performance Data

Pressure Radius Flow Precip in/hr
Nozzle PSI ft. GPM
40 40
50
60
41'
42'
42'
7.0
8.0
8.5
0.80
0.87
0.93
0.93
1.01
1.07
41 50
60
70
80
44'
44'
45'
46'
10.2
11.1
12.1
13.0
1.01
1.10
1.15
1.18
1.17
1.27
1.33
1.37
42 50
60
70
80
46'
47'
49'
50'
11.0
12.3
13.1
13.9
1.00
1.07
1.05
1.07
1.16
1.24
1.21
1.24
43 50
60
70
80
51'
52'
52'
53'
13.5
15.1
16.1
17.5
1.00
1.07
1.15
1.20
1.15
1.24
1.32
1.38
44 60
70
80
90
58'
58'
60'
60'
20.0
21.8
23.4
24.9
1.14
1.25
1.25
1.33
1.32
1.44
1.44
1.54
45 60
70
80
90
60'
62'
64'
65'
22.7
24.7
26.4
28.2
1.21
1.24
1.24
1.28
1.40
1.43
1.43
1.48


Note: To ensure optimum nozzle performance, the rotor should be operated in the "Recommended pressure range." The sprinkler will work normally when used in the "Operating pressure range", but nozzle performance may be reduced.
I-40 Dual Opposing Nozzle Performance Data

Pressure Radius Flow Precip in/hr
Nozzle PSI ft. GPM
15
Gray
50
60
70
80
52'
54'
56'
57'
13.0
13.2
14.4
15.5
0.46
0.44
0.44
0.46
0.53
0.50
0.51
0.53
18
Red
50
60
70
80
58'
59'
60'
62'
13.7
15.2
16.6
17.8
0.39
0.42
0.44
0.45
0.45
0.49
0.51
0.51
20
Dk. Brown
60
70
80
90
63'
64'
66'
66'
19.1
20.9
22.3
23.9
0.46
0.49
0.49
0.53
0.53
0.57
0.57
0.61
23
Dk. Green
60
70
80
90
65'
66'
67'
68'
20.4
22.3
24.0
25.6
0.46
0.49
0.51
0.53
0.54
0.57
0.59
0.62
25
Dk. Blue*
60
70
80
90
66'
68'
69'
70'
22.0
24.0
25.9
27.2
0.49
0.50
0.52
0.53
0.56
0.58
0.60
0.62
28
Black
70
80
90
100
70'
72'
74'
76'
28.9
30.9
32.9
33.7
0.57
0.57
0.58
0.56
0.66
0.66
0.67
0.65
I-41 Nozzle Performance Data – Metric

Pressure Radius Flow Precip mm/hr
Nozzle Bars kPa m m3/hr l/min
40 2.5
3.0
3.5
4.0
4.5
5.0
248
303
352
400
448
496
13.4
13.7
14.0
14.0
14.0
14.3
1.52
1.68
1.80
1.92
2.03
2.13
25.4
28.0
30.0
32.0
33.8
35.5
17
18
18
20
21
21
20
21
21
23
24
24
41 3.0
3.5
4.0
4.5
5.0
5.5
303
352
400
448
496
552
14.9
15.2
15.5
15.5
15.8
16.2
2.16
2.33
2.49
2.64
2.79
2.95
36.0
38.9
41.5
44.1
46.5
49.1
19
20
21
22
22
23
22
23
24
25
26
26
42 3.0
3.5
4.0
4.5
5.0
5.5
303
352
400
448
496
552
15.2
15.5
16.2
16.5
16.8
17.1
2.37
2.54
2.71
2.87
3.01
3.17
39.4
42.4
45.2
47.8
50.2
52.9
20
21
21
21
21
22
24
24
24
24
25
25
43 3.0
3.5
4.0
4.5
5.0
5.5
303
352
400
448
496
552
16.8
17.1
17.4
17.7
18.0
18.6
2.87
3.11
3.33
3.55
3.75
3.97
47.9
51.8
55.6
59.1
62.4
66.1
20
21
22
23
23
23
24
25
26
26
27
26
44 4.0
4.5
5.0
5.5
6.0
6.5
400
448
496
552
600
648
19.2
19.5
19.8
20.1
20.1
20.4
4.47
4.75
5.02
5.31
5.56
5.80
74.4
79.1
83.6
88.5
92.6
96.6
24
25
26
26
27
28
28
29
30
30
32
32
45 4.0
4.5
5.0
5.5
6.0
6.5
400
448
496
552
600
648
20.1
20.4
20.7
21.0
21.3
21.6
5.07
5.38
5.68
6.01
6.28
6.55
84.4
89.7
94.7
100.2
104.7
109.1
25
26
26
27
28
28
29
30
31
31
32
32

I-43 Nozzle Performance Data – Metric

Pressure Radius Flow Precip mm/hr
Nozzle Bars kPa m m3/hr l/min
40 2.5
3.0
3.5
4.0
4.5
248
303
352
400
448
12.2
12.5
12.8
12.8
13.1
1.52
1.68
1.80
1.92
2.03
25.4
28.0
30.0
32.0
33.8
20
21
22
23
24
24
25
25
27
27
41 3.0
3.5
4.0
4.5
5.0
5.5
303
352
400
448
496
552
13.1
13.4
13.4
13.4
13.7
14.0
2.16
2.33
2.49
2.64
2.79
2.95
36.0
38.9
41.5
44.1
46.5
49.1
25
26
28
29
30
30
29
30
32
34
34
35
42 3.0
3.5
4.0
4.5
5.0
5.5
303
352
400
448
496
552
13.7
14.0
14.3
14.6
14.9
15.2
2.37
2.54
2.71
2.87
3.01
3.17
39.4
42.4
45.2
47.8
50.2
52.9
25
26
26
27
27
27
29
30
30
31
31
32
43 3.0
3.5
4.0
4.5
5.0
5.5
303
352
400
448
496
552
14.9
15.5
15.8
15.8
15.8
16.2
2.87
3.11
3.33
3.55
3.75
3.97
47.9
51.8
55.6
59.1
62.4
66.1
26
26
27
28
30
30
30
30
31
33
34
35
44 4.0
4.5
5.0
5.5
6.0
6.5
400
448
496
552
600
648
17.7
17.7
17.7
18.3
18.3
18.3
4.47
4.75
5.02
5.31
5.56
5.80
74.4
79.1
83.6
88.5
92.6
96.6
29
30
32
32
33
36
33
35
37
37
38
40
45 4.0
4.5
5.0
5.5
6.0
6.5
400
448
496
552
600
648
18.3
18.6
18.9
19.5
19.8
19.8
5.07
5.38
5.68
6.01
6.28
6.55
84.4
89.7
94.7
100.2
104.7
109.1
30
31
32
32
32
33
35
36
37
36
37
39

* Factory-installed nozzle
Note: All precipitation rates calculated for 180 degree operation. For the precipitation rate for a 360 degree sprinkler, divide by 2. For more information on precipitation rates click here.
I-41 Dual Opposing Nozzle Performance Data – Metric

Pressure Radius Flow Precip mm/hr
Nozzle Bars kPa m m3/hr l/min
15
Gray
3.0
3.5
4.0
4.5
5.0
5.5
303
352
400
448
496
552
15.2
15.8
16.2
16.8
17.1
17.4
2.75
2.91
3.06
3.20
3.32
3.46
45.8
48.5
51.0
53.3
55.4
57.7
24
23
23
23
23
23
27
27
27
26
26
26
18
Red
3.0
3.5
4.0
4.5
5.0
5.5
303
352
400
448
496
552
17.4
17.7
18.0
18.0
18.3
18.9
2.90
3.15
3.38
3.61
3.82
4.05
48.3
52.5
56.4
60.1
63.7
67.5
19
20
21
22
23
23
22
23
24
26
26
26
20
Dk. Brown
4.0
4.5
5.0
5.5
6.0
6.5
400
448
496
552
600
648
18.9
19.2
19.5
20.1
19.8
20.1
4.26
4.54
4.80
5.08
5.32
5.55
71.1
75.6
80.0
84.7
88.7
92.5
24
25
25
25
27
27
28
28
29
29
31
32
23
Dk. Green
4.0
4.5
5.0
5.5
6.0
6.5
400
448
496
552
600
648
19.5
19.8
20.1
20.4
20.7
20.7
4.55
4.85
5.14
5.45
5.71
5.96
75.8
80.8
85.6
90.8
95.1
99.4
24
25
25
26
27
28
28
29
29
30
31
32
25
Dk. Blue*
4.0
4.5
5.0
5.5
6.0
6.5
400
448
496
552
600
648
20.1
20.4
20.7
21.0
21.3
21.3
4.92
5.23
5.52
5.84
6.10
6.36
82.1
87.2
92.0
97.3
101.7
106.0
24
25
26
26
27
28
28
29
30
30
31
32
28
Black
4.5
5.0
5.5
6.0
6.5
7.0
448
496
552
600
648
696
21.0
21.3
21.9
22.3
22.6
23.2
6.38
6.68
7.00
7.27
7.52
7.76
106.4
111.3
116.7
121.1
125.3
129.4
29
29
29
29
30
29
33
34
34
34
34
33