EC Components (Outdoor Model)
This section will give you a brief overview of some of the components on the outdoor version of the EC. Each item will be discussed in further detail later, however this section can be helpful in getting acquainted with the different options available.
A LCD Display (See Indoor Model for LCD Display Detail Illustration)
B Control Buttons
Button Increases the selected flashing display.
Button Decreases the selected flashing display.
Button Advances the selected flashing display to the next item.
Button Selects program A, B or C for different watering zone requirements.
C High Voltage Wiring Compartment
Route AC power cable and conduit through the 1/2" (13 mm) conduit opening on the the left side of the bottom of the cabinet and connect the wires to the AC terminal strip located inside the junction box door below the transformer. Always use a local authority approved conduit 1/2" (13 mm) male adapter when installing the AC wiring. Insert the adapter (male threads first) into the 1/2" (13 mm) hole at the bottom of the controller until it enters the wiring enclosure. Attach the nut to the adapter inside the enclosure. It is recommended that the power installation be performed by a licensed electrician.
A key feature of the EC is its clear, easy-to-use dial design that makes programming a snap. All essential keypad functions are clearly marked to eliminate the confusion thats a characteristic of so many other controllers.
D Control Dial
 |
Automatic Normal dial position for all controller automatic and manual operation. |
 |
Current Time/Day Allows current day and clock time to be set. |
 |
Start Times Allows 1 to 4 start times to be set in each program. |
 |
Run Times Allows user to set each valve station run time from 1 minute to 4 hours. |
 |
Water Days Allows user to select individual days to water or a selected number of days between waterings (interval). |
 |
Seasonal Adjustment Allows user to make run time changes according to the seasons without reprogramming. |
 |
Manual-One Station Allows user to activate a one time watering of a single valve station. |
 |
Manual-All Stations Allows user to activate a one time watering of all valve stations or a few selected stations. |
 |
System Off Allows user to discontinue all programs and stop all watering. Also allows the user to set the controller to a timed off until dial is returned to the Automatic position. |
E Wiring Compartment
- 9-Volt Battery Connector The alkaline battery can be used to program the controller in the absence of AC power. Even without a 9-volt battery the EC will keep track of time for up to 1 month and retain the program indefinitely in the event of a power outage.
- Battery Compartment Compartment for the 9-volt battery.
- Terminal Strip Area Use to attach valve wires from their source to the controller.
- Reset Button Use to reset the controller.
|