Connecting an SRR or ICR Remote Control (Not Included)

The ICC controller is shipped with a SmartPort® wiring harness, allowing for fast and easy use of the Hunter SRR or ICR remote control. The remote makes it possible for contractors and end users alike to operate a system without having to walk back and forth to the controller.

To utilize the SRR or ICR Remote Control System you must install the SmartPort outlet.

  1. Install a 1/2" female threaded “Tee” in the field wiring conduit approximately 12" below the ICC.
  2. Feed the red, white, and blue wires of the harness through the base of the “Tee” and into the wiring compartment as shown in below.
  3. Screw the SmartPort harness housing into the “Tee” as shown.
  4. Access the terminal strip area and attach the red wire to the bottom most AC screw slot, attach the white wire to the upper AC screw slot and attach the blue wire to the screw slot marked “REM.”

The SmartPort is now ready for remote control use.

NOTE: Any extension of the wiring on the SmartPort® may result in an error message in the controller display and possible malfunction of the remote unit due to radio interference. In some situations, lengthening of the harness may work fine, in others it may not work at all (it is site specific). In either case, extending the wiring harness should be done using shielded cable to minimize the possible effects of electrical noise. For easiest installation, order a new Hunter SmartPort shielded cable wiring harness (part #SRR-SCWH) with a full 25 feet of shielded cable.