Specifications
Operating Specifications
- Station Run Time: 1 minute to 2 hours (in 1-minute increments) on programs A, B, and C. Up to 12 hours on program D. The longer run time on program D is primarily to accommodate drip irrigation applications.
- Start Times: 8 per day, per program, for up to 32 daily starts.
- Watering Schedule: 7-day calendar, interval watering up to a 31-day interval or true odd or even day programming, made possible by the 365-day clock/calendar.
Electrical Specifications
- Transformer Input: 120VAC, 60Hz (230VAC, 50/60 Hz International Use)
- Transformer Output: 25 VAC, 1.5 amp
- Station Output: 24VAC, .56 amps per station
- Maximum Output: 24VAC, 1.4 amps (includes Master Valve Circuit)
- Battery Backup: 9-volt alkaline battery (not included) used only for time keeping during power outages, the nonvolatile memory maintains program information
Dimensions
| Plastic Cabinet |
|
Metal Cabinet |
|
Metal Pedestal |
| Height: 11" (28 cm) |
|
Height: 15 3/4" (40 cm) |
|
Height: 30" (76 cm) |
| Width: 12" (30.5 cm) |
|
Width: 11 3/8" (29 cm) |
|
Width:11 3/8" (29 cm) |
| Depth: 3 3/4" (9.5 cm) |
|
Depth: 4" (11.4 cm) |
|
Depth: 4" (10 cm) |
Default Settings
All stations are set to zero run time. This controller has a nonvolatile memory that retains all entered program data even during power outages, without need for a battery.
|