Connecting a Pump Start Relay
NOTE: Complete this section only if you have a pump start relay installed. A pump start relay is an electronic device that uses a current from the controller to actuate a separate electrical circuit to energize a pump to provide water to your system.
The controller should be mounted at least 15 feet (4.5m) away from both the pump start relay and the pump. When a pump start relay comes on it sends out surges that may potentially cause damage to a controller that is mounted to close. When a pump is to be operated by the controller, a pump start relay must be used. Hunter offers a full range of pump start relays for most applications.
- Route a wire pair from the pump relay into the controller housing.
- Connect common wire to the screw slot C (Common) and the remaining wire from the pump relay to the MV screw slot.
Relay current draw must not exceed .35 Amps. Do not connect controller directly to pump damage to controller can result.
|