Programming the Controller (Continued)

Selecting Odd or Even Days

This feature will use a numbered day of the month for watering instead of specific days of the week (Odd days 1st, 3rd, 5th, etc.; Even days 2nd, 4th, 6th, etc.)

  1. Press the button until the arrow cursor is above either EVEN or ODD on the display.
  2. Press the button to select or the button to cancel either Odd Days or Even Days. The previous selected days of the week will revert to active if Odd Days or Even Days is cancelled.

NOTE: The 31st of any month and February 29 are always “off” days if Odd watering is selected.

Run

After programming is complete, turn the dial to RUN to enable automatic execution of all selected programs and start times. Watering will not occur unless dial is in the RUN or RUN (SENSOR BYPASS) position.

Weather Sensor Bypass

With this built-in feature, there is no need for an additional manual bypass switch when using rain sensors. The SRC works with the Hunter Mini-Clik®, Rain-Clik™, Freeze-Clik® plus some other rain, wind or freeze sensors on the market today. If the sensor is preventing system operation, just turn the dial to RUN (BYPASS SENSOR) and the weather sensor will be overridden.

System Off

Valves currently watering will be shut off after the dial is turned to the SYSTEM OFF position for two seconds. All active programs are discontinued and watering is stopped. To return controller to normal automatic operation, simply return dial to RUN position.

Manually Run a Single Station

  1. Turn dial to the MANUAL-SINGLE STATION position.
  2. Station run time will flash in the display. Use the button to move to the next station. You may use the or button to select the amount of time for a station to water.
  3. Turn the dial clockwise to the RUN position to run the station (only the designated station will water, then the controller will return to automatic mode with no change in the previously set program).