Wiring DC Latching Solenoids to the WVC
Leads are provided to attach a Hunter DC latching solenoid or other two-wire, low-voltage latching solenoids to the WVC. (Hunter DC latching solenoid part #458200)
Hunter DC latching solenoids have two leads: one colored black and the other red.
To Connect DC Latching Solenoids:
- Select the appropriate station wire (red wire) on the WVC Note: Station numbers are identified on top of the WVC. Strip away 1/2" (13mm) of insulation from the station wire.
- Remove 1/2" (13mm) of insulation from the common wire (black wire) on the WVC.
- Twist the red and black leads from the solenoid to the red and black leads on the WVC as shown in the figure.
- Make sure that waterproof connectors are used to secure all wire connections.
NOTE: The maximum recommended distance from the WVC to any Hunter DC latching solenoid is approximately 100 feet with 18 gauge wire. Long distances between the WVC and the DC latching solenoid will reduce overall 9-volt battery life.
NOTE: The black wire from each solenoid must be wired to the single black lead on the WVC controller.
|