Flow-Clik Components (continued)
D. System Status Indicator
The Flow-Clik Interface Box has a System Status indicator LED that provides information on the current status of the Flow-Clik system.
GREEN indicates power is applied to the sensor, but no flow is occurring
FLASHING GREEN indicates an acceptable amount of water is flowing (below the flow sensor calibrated maximum)
FLASHING RED indicates that overflow is occurring (Water flow in excess of the calibrated maximum)
RED indicates an unacceptable amount of water was flowing and the system has been shut down. (Water flow exceeded the calibrated maximum for a time period longer than the startup delay).
ALTERNATING RED/GREEN indicates that system overflow occurred during an automatic watering cycle (press the Restart/Calibrate button to reset the system status indicator.
YELLOW indicates that the Flow-Clik is calibrating the sensor to the system flow).
|