Specifications
Operating Specifications
Temperature: 0 to 150 degrees F
Pressures: up to 200 psi
Humidity: up to 100%
Additional Features
Programmable Start Up Delay (0 to 300 seconds)
Programmable Interrupt Period (5 to 60 minutes)
System Status Indicator Light
One Button System Calibration
| FLOW RANGE |
|
Flow Sensor
Diameter
|
Operating Range (GPM)
|
|
Minimum*
|
Suggested
Maximum**
|
Maximum
|
|
1"
|
6
|
17
|
50
|
|
1 1/2"
|
13
|
35
|
100
|
|
2"
|
20
|
55
|
200
|
|
3"
|
40
|
120
|
300
|
* Minimum recommended flow for the highest flow zone for your system
** Good design practice dictates the maximum flow not to exceed 5ft/sec.Suggested maximum flow is based upon Class 200 IPS plastic pipe
Electrical Specifications
Current Draw: (@ 24 VAC) .025 amps
Switching Current: 2.0 amps
Maximum Distance between Interface Box and Sensor = 1,000 ft.
Dimensions
Flow-Clik Sensor Body:
FCT 100 - 4.8"H x 2.3"W x 4.5"L
FCT 150 - 5.4"H x 2.3"W x 4.6"L
FCT 158 - 5.4"H x 2.3"W x 5.1"L
FCT 200 - 5.9"H x 2.7"W x 4.7"L
FCT 208 - 6.0"H x 2.9"W x 5.4"L
FCT 300 - 7.0"H x 4.0"W x 6.2"L
FCT 308 - 7.0"H x 4.2"W x 6.4"L
Interface Panel: