Hunter Technical Support Document

How do I manually open a valve?

Product Lines:
Topics: 
FAQs, Troubleshooting, Video

There are two ways to bleed a zone valve for manual operation:

  • One way is to simply turn the solenoid (the black cylinder with 2 wires) counter-clockwise a 1/4 to 1/2 turn. To shut off the valve, twist the solenoid clockwise until it is snug on the valve.
  • The other way is to use the bleed screw the same way, loosen the screw enough to realease air (1/4 to 1/2 turn). Hand tighten the screw to shut the valve off.

 

 

Rate this Article: 
No votes yet

Still not finding the answers?

View more support documents

Hunter Technical Support experts are available to answer your question(s) about Hunter products and their usage. Simply click on the contact button below to submit an email request.