Hunter Industries
Published on Hunter Industries (http://www.hunterindustries.com)

Home > Products > Products > Irrigation Products > Valves > PGV

PGV

PGV

Professional Grade Valves Ready for All System Sizes

This hard working, heavy-duty valve offers the best features of Hunter’s top-of-the-line valves. Built with enough durability to handle the rigors of most residential and light commercial sites, the PGV is available in an array of configurations. For smaller landscape applications, the PGV is available in four 25 mm body configurations: angle, globe, or male x male design. In turn, each model is available in either a flow control or non-flow control version. For larger landscape applications, the PGV comes in both 40 mm and 50 mm globe/angle models (with flow control). All models feature durable high-grade construction and a rugged diaphragm with support to prevent stress failure.

Product Tabs

Features
  • Application (PGV-100): Residential

  • Application (PGV-101, 151, 201): Residential/light commercial

  • Sizes: 1" (25 mm); 1½" (40 mm); 2" (50 mm)

  • External and internal manual bleed allows quick and easy “at the valve” activation

  • Double-beaded diaphragm seal design for superior leak-free performance

  • Optional: DC latching solenoids enable Hunter’s battery-powered controllers

  • Captive bonnet bolts provide hassle-free valve maintenance

  • Low flow capability allows use of Hunter’s micro-irrigation products

  • Encapsulated 24 VAC solenoid with captive plunger for hassle-free service

  • Temperature rating: 66° C

  • Warranty period: 2 years

Flow Control [1]

Maximize efficiency and prolong the life of a system by fine tuning flow and pressure for each zone.

Accu-Sync™ Pressure Regulation [2]

Avoid sprinkler over-pressure conditions and experience significant water savings with Hunter's Accu-Sync pressure regulator. This option is available in adjustable pressure or fixed pressure models.

Reclaimed Water Identification [3]

Violet tags and handles are an option for a clear, quick, and simple method of identifying the use of non-potable water.

Valve Models

PGV-101, PGV-100JT, PGV101JT

  • Reclaimed Water Handle P/N: 269205

PGV-151, PGV-201

  • Reclaimed Water Handle P/N: 607105

ICV101, ICV151, ICV201

  • Reclaimed Water Handle P/N: 561205

ICV301

  • Reclaimed Water Handle P/N: 515005
Models

PGV Model Chart

 

PGV-100G
Inlet / Outlet: 1"

PGV-151
Inlet / Outlet: 1½"

PGV-201
Inlet / Outlet: 2"

Height 13 cm 19 cm 20 cm
Length 11 cm 15 cm 17 cm
Width 6 cm 11 cm 13 cm

PGV Pressure Loss in kPa

Flow
l/min
1" Globe 1½" Globe 1½" Angle 2" Globe 2" Angle
4 8        
20 9.5        
40 13        
55 11        
75 22 20 22 4 9
95 31 20 21 5.5 9
115 62 21 21 7.5 9.5
135 112 22 21 9 10
150 139 25 23 12 11
200   27 24 14 12
325   47 41 26 19
400   65 59 33 24
500   96 92 43 32
625       56 45
775       74 64

PGV Pressure Loss in Bar

Flow
m3/hr
1" Globe 1½" Globe 1½" Angle 2" Globe 2" Angle
0.3 0.1        
1.0 0.1        
2.5 0.1        
3.5 0.2        
4.5 0.2 0.2 0.2 0.1 0.1
7.0 0.4 0.2 0.2 0.1 0.1
8.0 1.0 0.2 0.2 0.1 0.1
9.0 1.0 0.2 0.2 0.1 0.1
11.0   0.3 0.2 0.1 0.1
13.5   0.3 0.3 0.1 0.1
18.0   0.4 0.4 0.2 0.1
22.5   0.6 0.5 0.3 0.2
27.0   0.8 0.8 0.4 0.3
30.5       0.6 0.5
34.0       0.7 0.6

SPECIFICATION BUILDER

MODELS

INLET/OUTLET

OPTIONS
FACTORY INSTALLED

OPTIONS
USER INSTALLED

PGV-100G = 1" (25 mm) Globe valve, no flow control

B = BSP threads

S = Slip x slip (excludes PGV-100A, PGV-151
and PGV-201)

(blank) = No option
DC = DC latching solenoid
LS = Valve without solenoid

(blank) = No option
R = Reclaimed water ID handle
(except PGV-100)

CC = Solenoid conduit cover
DC = DC latching solenoid
AS-ADJ = Accu-Sync adjustable pressure regulator
AS-20 = Accu-Sync 20: 1.4 bar pressure regulator
AS-30 = Accu-Sync 30: 2.1 bar pressure regulator
AS-40 = Accu-Sync 40: 2.8 bar pressure regulator
AS-50 = Accu-Sync 50: 3.5 bar pressure regulator
AS-70 = Accu-Sync 70: 4.8 bar pressure regulator

PGV-101G = 1" (25 mm) Globe valve, with flow control
PGV-100A = 1" (25 mm) Angle valve, no flow control
PGV-101A = 1" (25 mm) Angle valve, with flow control
PGV-151 = 1½" (40 mm) Globe/angle valve, with flow control
PGV-201 = 2" (50 mm) Globe/angle valve, with flow control
PGV-100 = 1" (25 mm) Globe valve, no flow control

MMB = Male x male (BSP)

PGV-101 =  1" (25 mm) Globe valve, with flow control

EXAMPLES

PGV-101G - B - DC

1" (25 mm) globe valve, with flow control, Female BSP threads, and DC latching solenoid

PGV-151 - B - AS 1½" (40 mm) globe valve, with flow control, female BSP threads, and Accu-Sync™ pressure regulator

 

SRV & PGV Valve Comparison Chart

View ICV & IBV Valves >> [4]

Keep Residential Landscapes Running Smooth
Valves are the heart of an irrigation system. Hunter has assembled one of the broadest line-ups in the industry to suit any residential system.

[5]

[6]

[7]

  SRV [5] PGV Jar-Top [6] PGV [7]
QUICK SPECS
Size 1" BSP 1" BSP 1", 1½", 2" BSP
Flow (m3/hr) 0.25 - 9.00 0.05 - 9.00 0.05 - 34.00
Flow (l/min) 4.0 - 150 0.7 - 150 0.7 - 570
FEATURES
Captive Bonnet Bolts  
Warranty 2 Years 2 Years 2 Years
ADVANCED FEATURES
Flow Control   Optional Optional
ACCU-SYNC Capable
Reclaimed Water ID Handle   Field Installed Field Installed
Applications
Residential
Commericial    
Potable water
Pressure regulation
Low pressure systems
Specifications

Operating Specifications

  • Flow rate:
    • PGV-100: 0.05 to 9 m3/hr 0.7 to 150 l/min
    • PGV-101: 0.05 to 9 m3/hr 0.7 to 150 l/min
    • PGV-151: 5 to 27 m3/hr, 75 to 450 l/min
    • PGV-201: 5 to 34 m3/hr, 75 to 570 l/min
  • Recommended pressure range: 1.5 to 10 bar; 150 to 1000 kPa

Solenoid Specifications

  • 24 VAC solenoid
    • 350 mA inrush, 190mA holding, 60 HZ
    • 370 mA inrush, 210mA holding, 50 HZ

Factory Installed Options

  • Valve without solenoid
  • DC latching solenoid

User Installed Options

  • Solenoid conduit cover (P/N 464322)
  • DC latching solenoid (P/N 458200)
  • Accu-Sync pressure regulator
  • Reclaimed water ID handle for PGV-101 models (P/N 269205) and PGV-151/201 models (P/N 607105)
Resources

Literature

[8]
USAUSA [8]
MetricMetric [9]
EspañolEspañol [10]
ItalianoItaliano [11]
FrançaisFrançais [12]
DeutschDeutsch [13]
[14]
PGV Brochure [8]

Photos

[15]
USAUSA [15]
[14]
PGV Photos [15]

Specifications

[16]
USAUSA [16]
MetricMetric [17]
[14]
PGV Installation Detail - DWG [16]
[18]
USAUSA [18]
MetricMetric [19]
[14]
PGV Installation Detail - DXF [18]
[20]
USAUSA [20]
MetricMetric [21]
[14]
PGV Installation Detail - PDF [20]
[22]
USAUSA [22]
[14]
PGV Written Specification [22]
[23]
USAUSA [23]
[14]
Automatic Control Valves - Written Specifications - MasterSpec® [23]

Video

[24]
USAUSA [24]
[14]
Valve Series: Cleaning the Diaphragm on a Valve [24]
[25]
USAUSA [25]
[14]
Valve Series: Troubleshooting a Valve that is not Opening [25]
[26]
USAUSA [26]
[14]
Valve Series: Valve Operation [26]
Support
TopicTitle [27]Rating [28]
No support documents found.

Source URL (retrieved on 22/05/2013 - 10:06): http://www.hunterindustries.com/node/919

Links:
[1] http://www.hunterindustries.com/node/252
[2] http://www.hunterindustries.com/node/255
[3] http://www.hunterindustries.com/node/9691
[4] http://www.hunterindustries.com/node/28326
[5] http://www.hunterindustries.com/product/valves/srv
[6] http://www.hunterindustries.com/product/valves/pgv-jar-top
[7] http://www.hunterindustries.com/product/valves/pgv
[8] http://www.hunterindustries.com/sites/default/files/BR_PGV_dom.pdf
[9] http://www.hunterindustries.com/sites/default/files/BR_PGV_em.pdf
[10] http://www.hunterindustries.com/sites/default/files/BR_PGV_sp.pdf
[11] http://www.hunterindustries.com/sites/default/files/BR_PGV_IT.pdf
[12] http://www.hunterindustries.com/sites/default/files/BR_PGV_fr.pdf
[13] http://www.hunterindustries.com/sites/default/files/BR_PGV_gr.pdf
[14] http://www.hunterindustries.com/global
[15] http://www.hunterindustries.com/sites/default/files/productimagepack_valve_PGV.zip
[16] http://www.hunterindustries.com/sites/default/files/PGVImperialDWG.zip
[17] http://www.hunterindustries.com/sites/default/files/PGVMetricDWG.zip
[18] http://www.hunterindustries.com/sites/default/files/PGVImperialDXF.zip
[19] http://www.hunterindustries.com/sites/default/files/PGVMetricDXF.zip
[20] http://www.hunterindustries.com/sites/default/files/PGVImperialPDF.zip
[21] http://www.hunterindustries.com/sites/default/files/PGVMetricPDF.zip
[22] http://www.hunterindustries.com/sites/default/files/WS_PGV.DOC
[23] http://www.hunterindustries.com/sites/default/files/MS_Automatic_Control_Valves.DOC
[24] http://www.hunterindustries.com/media/3116/colorbox-ajax?iframe=true&scrolling=no&height=490&width=660
[25] http://www.hunterindustries.com/media/3118/colorbox-ajax?iframe=true&scrolling=no&height=490&width=660
[26] http://www.hunterindustries.com/media/3115/colorbox-ajax?iframe=true&scrolling=no&height=490&width=660
[27] http://www.hunterindustries.com/print/919?solrsort=sort_label%20asc#node_product_full_group_support_tab
[28] http://www.hunterindustries.com/print/919?solrsort=is_rating%20asc#node_product_full_group_support_tab