Hunter Industries
Published on Hunter Industries (http://www.hunterindustries.com)

Home > Products > Products > Irrigation Products > Valves > ICV

ICV

ICV

Top of the Line Valve for High-Pressure Commercial Systems

In order to create a plastic valve that can consistently operate at 15 bar, Hunter relies on only materials that are both time and contractor proven. Created to handle the wide range of conditions different sites will bring, the ICV valve includes both a fabric reinforced EPDM diaphragm and seat, and flow control as standard features. It can consistently withstand pressures of up to 15 bar while handling the continual hammer that such forces will produce. Plus, it’s exceptionally easy to service, with bonnet bolts that can be loosened and tightened using a variety of common contractor tools. A Filter Sentry™ option is also available for applications that involve dirty water. The Filter Sentry™ system keeps the the valve filter screen free of debris commonly found in non-potable water sources.

Product Tabs

Features
  • Application: Commercial/municipal

  • Sizes: 1" (25 mm); 1½" (40 mm); 2" (50 mm)

  • External and internal manual bleed allows quick and easy “at the valve” activation

  • Glass-filled nylon construction resulting in the highest pressure rating

  • Double-beaded diaphragm seal design for superior leak-free performance

  • Fabric-reinforced EPDM diaphragm and EPDM seat ensure superior performance in all conditions

  • Optional: DC latching solenoids enable Hunter’s battery-powered controllers

  • Captive bonnet bolts provide hassle-free valve maintenance

  • Low flow capability allows use Hunter’s micro-irrigation products

  • Encapsulated 24 VAC solenoid with captive plunger for hassle-free service

  • Temperature rating: 66° C

  • Warranty period: 5 years

Flow Control [1]

Maximize efficiency and prolong the life of a system by fine tuning flow and pressure for each zone.

Filter Sentry™ [2]

The Filter Sentry scours the filter clean with a wiper that slides up and covers the entire screen when the valve opens. Even more, the wiper continues to scrub the filter's upper part during valve operation. The Filter Sentry can be added after the valve is installed as well.

Accu-Sync™ Pressure Regulation [3]

Avoid sprinkler over-pressure conditions and experience significant water savings with Hunter's Accu-Sync pressure regulator. This option is available in adjustable pressure or fixed pressure models.

Reclaimed Water Identification [4]

Violet tags and handles are an option for a clear, quick, and simple method of identifying the use of non-potable water.

Valve Models

PGV-101, PGV-100JT, PGV101JT

  • Reclaimed Water Handle P/N: 269205

PGV-151, PGV-201

  • Reclaimed Water Handle P/N: 607105

ICV101, ICV151, ICV201

  • Reclaimed Water Handle P/N: 561205

ICV301

  • Reclaimed Water Handle P/N: 515005
Models

ICV Models Chart

 

ICV-101G
Inlet Diameter: 1"

ICV-151G
Inlet Diameter: 1-1/2"

ICV-201G
Inlet Diameter: 2"

ICV-301
Inlet Diameter: 3"

Height 14 cm 18 cm 18 cm 27.3 cm
Length 12 cm 17.5 cm 17.5 cm 23.5 cm
Width 10.2 cm 14 cm 14 cm 18.7 cm

ICV Pressure Loss in kPa

Flow
l/min
1"
Globe
1-1/2"
Globe
2"
Globe
3"
Globe
3" Angle
1 14        
2 14        
4 14        
20 17        
40 20        
60 20        
75 20 9.6      
115 62 10      
150 139 12 5.0    
190   15 7.0    
225   18 9.3    
280   26 14    
340   37 20    
380   46 26    
450   65 36    
510   84 47    
565   104 57 16 12
660     79 22 17
750     103 29 23
850       38 30
950       47 38
1050       58 47
1135       69 56

ICV Pressure Loss in Bar

Flow
m3/hr
1"
Globe
1-1/2"
Globe
2"
Globe
3"
Globe
3" Angle
0.05 0.1        
0.1 0.1        
0.3 0.1        
1.0 0.2        
2.5 0.2        
3.5 0.2        
4.5 0.2 0.1      
7.0 0.4 0.1      
9.0 1.0 0.1 0.1    
11.0   0.2 0.1    
13.5   0.2 0.1    
17.0   0.3 0.1    
20.5   0.4 0.2    
23.0   0.5 0.3    
27.0   0.7 0.4    
30.5   0.9 0.5    
34.0   1.2 0.6 0.2 0.1
40.0     0.9 0.2 0.2
45.5     1.2 0.3 0.2
51.0       0.3 0.3
57.0       0.4 0.4
62.5       0.5 0.5
68.0       0.6 0.6

SPECIFICATION BUILDER

MODELS

INLET/OUTLET

OPTIONS
FACTORY INSTALLED

OPTIONS
USER INSTALLED

ICV-101G = 1" (25 mm) globe valve

B = BSP threads

(blank) = No option
FS = Filter Sentry
DC = DC latching solenoid

 

(blank) = No option
R = Reclaimed water ID handle
CC = Solenoid conduit cover
DC = DC latching solenoid
AS-ADJ = Accu-Sync adjustable pressure regulator
AS-20 = Accu-Sync 20: 1.4 bar pressure regulator
AS-30 = Accu-Sync 30: 2.1 bar pressure regulator
AS-40 = Accu-Sync 40: 2.8 bar pressure regulator
AS-50 = Accu-Sync 50: 3.5 bar pressure regulator
AS-70 = Accu-Sync 70: 4.8 bar pressure regulator

ICV-151G = 1½" (40 mm) globe valve
ICV-201G = 2" (50 mm) globe valve
ICV-301 = 3" (80 mm) globe/angle valve

EXAMPLES

ICV-101G - B

1" (25 mm) globe valve,  threads

ICV-151G - B - FS - R 1½" (40 mm) globe valve, BSP threads, Filter Sentry, and reclaimed water ID handle
ICV-301 - B 3" (80 mm) globe/angle valve, BSP threads

 

ICV & IBV Comparison Chart

<< View SRV & PGV Valves [5]

Premium Valves That
Can Conquer All

Low flow to high flow, clean water to dirty water, low pressure to high pressure, Hunter provides a valve option that can handle any situation for years to come.

[6]

[6]

[7]

[7]

  ICV [6] ICV Filter Sentry™ [6] IBV [7] IBV Filter Sentry™ [7]
QUICK SPECS
Size 1", 1½", 2", 3" BSP 1", 1½", 2", 3" BSP 1", 1½", 2", 3" BSP 1", 1½", 2", 3" BSP
Flow (m3/hr) 0.05 - 68.00 0.05 - 68.00 0.05 - 68.00 0.05 - 68.00
Flow (l/min) 0.4 - 1135 0.4 - 1135 0.4 - 1135 0.4 - 1135
FEATURES
Captive Bonnet Bolts    
EPDM Diaphragm and Seat Standard Standard Standard Standard
Warranty 5 Years 5 Years 5 Years 5 Years
ADVANCED FEATURES
Flow Control
Filter Sentry Field Installed Factory Installed Field Installed Factory Installed
ACCU-SYNC Capable
Reclaimed Water ID Handle Field Installed Factory Installed    
Reclaimed Water ID Tag Field Installed Factory Installed Field Installed Field Installed
Applications
Residential      
Commericial
Potable water
Reclaimed water
Secondary water    
Pressure regulation
High pressure systems
Low pressure systems
High Temperature locations
Specifications

Operating Specifications

  • Flow rate:
    • ICV-101G: 0.06 to 9 m3/hr; 0.4 to 150 l/min
    • ICV-151G: 4 to 31 m3/hr; 75 to 510 l/min
    • ICV-201G: 9 to 34 m3/hr; 150 to 560 l/min
    • ICV-301: 34 to 68 m3/hr; 560 to 1135 l/min
  • Recommended pressure range: 1.5 to 15.0 bar; 150 to 1500 kPa

Solenoid Specifications

  • 24 VAC solenoid
    • 350 mA inrush, 190 mA holding, 60 HZ
    • 370 mA inrush, 210 mA holding, 50 HZ

Factory Installed Options

  • DC latching solenoid
  • Filter Sentry

User Installed Options

  • Solenoid conduit cover (P/N 464322)
  • DC latching solenoid (P/N 458200)
  • Accu-Sync pressure regulator
  • Reclaimed water ID handle for ICV101, 151, 201 (P/N 561205) and 301 (P/N 515005)
  • Reclaimed water ID Tag for all ICV valves (P/N 700392) (Included on Filter Sentry Models)
Resources

Literature

[8]
USAUSA [8]
MetricMetric [9]
EspañolEspañol [10]
ItalianoItaliano [11]
FrançaisFrançais [12]
DeutschDeutsch [13]
TürkçeTürkçe [14]
[15]
ICV Brochure [8]
[16]
USAUSA [16]
[15]
ICV Product Spec Cut Sheet [16]

Specifications

[17]
USAUSA [17]
MetricMetric [18]
[15]
ICV Installation Detail - DWG [17]
[19]
USAUSA [19]
MetricMetric [20]
[15]
ICV Installation Detail - DXF [19]
[21]
USAUSA [21]
MetricMetric [22]
[15]
ICV Installation Detail - PDF [21]
[23]
USAUSA [23]
[15]
ICV Written Specification [23]
[24]
USAUSA [24]
[15]
Automatic Control Valves - Written Specifications - MasterSpec® [24]

Video

[25]
USAUSA [25]
[15]
Valve Series: Cleaning the Diaphragm on a Valve [25]
[26]
USAUSA [26]
[15]
Valve Series: Troubleshooting a Valve that is not Opening [26]
[27]
USAUSA [27]
[15]
Valve Series: Valve Operation [27]
Support
TopicTitle [28]Rating [29]
No support documents found.

Source URL (retrieved on 24/05/2013 - 16:02): http://www.hunterindustries.com/node/922?solrsort=sort_label%2520asc

Links:
[1] http://www.hunterindustries.com/node/252
[2] http://www.hunterindustries.com/node/254
[3] http://www.hunterindustries.com/node/255
[4] http://www.hunterindustries.com/node/9691
[5] http://www.hunterindustries.com/node/28321
[6] http://www.hunterindustries.com/irrigation-product/valves/icv
[7] http://www.hunterindustries.com/irrigation-product/valves/ibv
[8] http://www.hunterindustries.com/sites/default/files/BR_ICV_dom.pdf
[9] http://www.hunterindustries.com/sites/default/files/BR_ICV_em.pdf
[10] http://www.hunterindustries.com/sites/default/files/BR_ICV_sp.pdf
[11] http://www.hunterindustries.com/sites/default/files/BR_ICV_it.pdf
[12] http://www.hunterindustries.com/sites/default/files/BR_ICV_fr.pdf
[13] http://www.hunterindustries.com/sites/default/files/BR_ICV_gr.pdf
[14] http://www.hunterindustries.com/sites/default/files/BR_ICV_tk.pdf
[15] http://www.hunterindustries.com/global
[16] http://www.hunterindustries.com/sites/default/files/PSCS_ICV_dom.pdf
[17] http://www.hunterindustries.com/sites/default/files/ICVImperialDWG.zip
[18] http://www.hunterindustries.com/sites/default/files/ICVMetricDWG.zip
[19] http://www.hunterindustries.com/sites/default/files/ICVImperialDXF.zip
[20] http://www.hunterindustries.com/sites/default/files/ICVMetricDXF.zip
[21] http://www.hunterindustries.com/sites/default/files/ICVImperialPDF.zip
[22] http://www.hunterindustries.com/sites/default/files/ICVMetricPDF.zip
[23] http://www.hunterindustries.com/sites/default/files/WS_ICV.doc
[24] http://www.hunterindustries.com/sites/default/files/MS_Automatic_Control_Valves.DOC
[25] http://www.hunterindustries.com/media/3116/colorbox-ajax?iframe=true&amp;scrolling=no&amp;height=490&amp;width=660
[26] http://www.hunterindustries.com/media/3118/colorbox-ajax?iframe=true&amp;scrolling=no&amp;height=490&amp;width=660
[27] http://www.hunterindustries.com/media/3115/colorbox-ajax?iframe=true&amp;scrolling=no&amp;height=490&amp;width=660
[28] http://www.hunterindustries.com/print/922?solrsort=sort_label%20asc#node_product_full_group_support_tab
[29] http://www.hunterindustries.com/print/922?solrsort=is_rating%20asc#node_product_full_group_support_tab