Use Dual to Convert The I-Core to A Cutting Edge Two-Wire Controller

DUAL is Hunter’s innovative two-wire plug-in for the I-Core controller. Designed to bring the convenience and efficiency of two-wire technology to all, the DUAL system can operate up to 48 zones via a single pair of wires, at distances up to 7,500 feet (2.3 km). The 48 zones can all be installed on a single path, or divided over multiple paths to take advantage of pipe trenches. Because it only requires two wires, DUAL offers unmatchable savings in labor, wire, and money. Since it’s I-Core compatible, system operators still receive advanced features and benefits like flow monitoring, quick system overview access, a factory-installed SmartPort®, six language capability, and a bold, graphic display. Dual decoders come in one and two-station versions. Aptly named Dual-1 and Dual-2, the decoder choices ensure any I-Core Dual system is customizable to the needs of any installation.

Product Tabs

Features
  • Two-wire decoder system for I-Core controllers

  • Decoder station sizes available: 1, 2

  • Field programmable decoders (no serial numbers to enter)

  • DUAL-S external surge arresters

  • DUAL decoder module display and push button programming makes it easy to program decoders at the controller itself

  • DUAL decoders can be field programmed with the Hunter ICD-HP. No need to remove decoders from the two-wire path

  • Decoder module displays decoder operation and diagnostic information

  • Waterproof connectors for connection to two-wire path included with all DUAL decoders and DUAL-S surge arrester

  • Can operate up to 48 stations of combined decoder and conventional control, making system retrofit easy

  • Number of 2-wire paths: 3

  • Solenoid finder feature assists in locating valves in the field.

Includes all features of the I-Core controller, plus decoder operations. [1]

The DUAL Decoder System starts with the I-Core controller and adds the benefits of a two-wire decoder system.

Programmable Decoders [2]

Field programmability means no lengthy serial numbers to enter in the controller, and no time lost re-programming decoder assignments after a controller change. Each decoder is programmed with its actual station (valve) numbers for simplicity and reliability. Decoders may be re-programmed at any time if desired.

Wireless Programming with ICD-HP [3]

All Hunter decoders feature wireless programming and diagnostic access from the ICD-HP handheld programmer. Patented technology allows programming and diagnostics through the housing of the decoder, without removing a single wire or waterproof connector. Program, operate, and diagnose decoders in-place in field valve boxes.

Color-Coded ID Wire [4]

Hunter’s unique jacketed decoder wire is high-strength, durable, sunlight protected, and part of the integrated lightning management system. Twisted pair conductors are color-coded for decoder system connections, and the outer jackets can be uniquely color-coded to organize field wire runs and assist in future wire tracking. Tough PE (polyethylene) jacket protects wire from sharp rocks and exposure to UV rays. Available in two standard wire gauges for different length requirements.

Waterproof Connectors Included [5]

Each Hunter decoder includes 2 DBRY-6 waterproof connector kits, UL listed to 600V direct burial. Only the best connectors will do in the critical two-wire path, but there is no need to go shopping for them separately. Suitable for all sizes of ID Wire connections.

Solar Sync Delay [6]

Solar Sync Delay allows the installer to specify a number of days before automatic weather adjustment from the Solar Sync sensor begins, as well as a global percentage to use during the delay period. This allows a period of non-adjusted irrigation for grow-in or plant establishment purposes, without requiring a return visit to the site to enable the Solar Sync water saving feature.

Models

DUAL Model Chart

DUAL Decoders
and Surge Arrestor

DUAL Decoder Module


BASE MODELS Plus DESCRIPTION

IC-600-PL

DUAL48M 48-Station controller, indoor/outdoor, plastic cabinet
IC-601-PL DUAL48M International version, 48-Station controller, indoor/outdoor, plastic cabinet
IC-600-M DUAL48M 48-Station controller, indoor/outdoor, metal cabinet
IC-600-PP DUAL48M 48-Station controller, indoor/outdoor, plastic pedestal
IC-600-SS DUAL48M 48-Station controller, indoor/outdoor, stainless steel cabinet

DUAL MODELS DESCRIPTION
DUAL48M DUAL decoder output module. Plug-in module converts any I-CORE
controller to 2-wire decoder system (up to 48 stations maximum)
DUAL-1 DUAL 1-station decoder (includes 2 DBRY-6 connectors)
DUAL-2 DUAL 2-station decoder (includes 2 DBRY-6 connectors)
DUAL-S DUAL surge arrestor (includes 4 DBRY-6 connectors)

ID WIRE MODEL GUIDE
14 AWG standard decoder cable 12 AWG long range,
heavy-duty decoder cable

ID1GRY

Gray jacket ID2GRY Gray jacket

ID1PUR

Purple jacket

ID2PUR

Purple jacket

ID1YLW

Yellow jacket

ID2YLW

Yellow jacket

ID1ORG

Orange jacket

ID2ORG

Orange jacket

ID1BLU

Blue jacket

ID2BLU

Blue jacket

ID1TAN

Tan jacket

ID2TAN

Tan jacket

ID WIRE Maximum Wire Runs
ID 1 Wire ID 2 Wire
5,000 ft with I-Core/Dual systems 7,500 ft with I-Core/Dual systems

10,000 ft with ACC/ICD systems

15,000 ft with ACC/ICD systems

Advanced AC Powered Controller Comparison Chart

<< View Residential AC Powered Controllers [7]

View Battery Powered Controllers >> [8]

“Smart” Control in Every Way
For large-scale commercial landscapes, Hunter provides a variety of traditional and two-wire control options with cutting edge advanced features that can keep any landscape green regardless of size

[9]

[10]

[11]

[12]

  I-Core [9] Dual [10] ACC [11] ACC Decoder [12]
QUICK SPECS
Number of Stations 6 to 42 1 to 48 12 to 42 1 to 99
Number of Programs 4 4 6 6
Valve Wire Options Conventional Two-wire Conventional Two-wire
Start Times Per Program 8 8 10 10
Max Number of Simultaneous Programs 2 2 6 6
Type* Modular Modular Modular Modular
FEATURES
Enclosure Type  Plastic Outdoor
Metal Outdoor
Stainless Outdoor
Plastic Pedestal
Stainless Pedestal
Plastic Outdoor
Metal Outdoor
Stainless Outdoor
Plastic Pedestal
Stainless Pedestal
Metal Outdoor
Stainless Outdoor
Plastic Pedestal
Stainless Pedestal
Metal Outdoor
Stainless Outdoor
Plastic Pedestal
Stainless Pedestal
Transformer Type Outdoor Outdoor Outdoor Outdoor
Central Control Compatible Yes (Fall '13) Yes (Fall '13) Yes Yes
Remote Control Compatible Yes Yes Yes Yes
Flow Monitoring Yes Yes Yes Yes
Solar Sync ET Sensor Compatible Yes Yes Yes Yes
Number of Sensor Inputs 2 (Plastic Models)
3 (Metal & Ped models)
2 (Plastic Models)
3 (Metal & Ped models)
4 + dedicated Flow input 4 + dedicated Flow input
Max Station Run Time (Hrs) 12 hr 12 hr 6 hr 6 hr
Pump/Master Valve output 1 1 2 2
Warranty 5 Years 5 Years 5 Years 5 Years
APPLICATION
Residential    
Light Commercial
Commercial

* Fixed or modular indicates the controllers ability to expand the number of stations from a base count.

Specifications

Dual Model Specifications

  • Decoder station sizes available: 1, 2
  • Dual-S external surge protectors (add in-line every 12th decoder or 1000 ft/300 m, minimum)
  • Max. distance to decoder
    • 14 AWG wire path; 5,000 ft.
    • 12 AWG wire path; 7,500 ft.
  • Max recommended distance, decoder to solenoid: 100 ft.
  • Field programmable:
    • Dual decoder module display and push button programming makes it easy to program decoders at the controller itself
    • Dual decoders can also be field programmed with the Hunter ICD-HP. No need to remove decoders from the two-wire path
  • Decoder module displays decoder operation and diagnostic information including current draw in milliamps
  • Can operate up to 48 stations of combined decoder and conventional control making system retrofit easy
  • Waterproof connectors for connection to two-wire path supplied with all Dual decoders and Dual-S surge protection
  • Number of two-wire paths: 3

Approvals

  • CE, UL, C-UL, C-tick, FCC

DUAL Specification Chart

 

DUAL decoders
and surge arrestor

DUAL decoder module

Height 3" 1-3/8"
Width 1-3/4" 4-3/8"
Depth 2"

4"

 

 

Resources

Literature

[13]
USAUSA [13]
MetricMetric [14]
EspañolEspañol [15]
ItalianoItaliano [16]
FrançaisFrançais [17]
PortuguêsPortuguês [18]
DeutschDeutsch [19]
[20]
Dual Brochure [13]
[21]
USAUSA [21]
[20]
Dual Product Spec Cut Sheet [21]
[22]
USAUSA [22]
MetricMetric [23]
EspañolEspañol [24]
ItalianoItaliano [25]
FrançaisFrançais [26]
DeutschDeutsch [27]
TürkçeTürkçe [28]
[20]
Decoder Design Guide [22]
[29]
USAUSA [29]
MetricMetric [30]
EspañolEspañol [31]
ItalianoItaliano [32]
FrançaisFrançais [33]
PortuguêsPortuguês [34]
DeutschDeutsch [35]
TürkçeTürkçe [36]
[20]
ICD-HP Brochure [29]

Manuals

[37]
USAUSA [37]
MetricMetric [38]
EspañolEspañol [39]
ItalianoItaliano [40]
FrançaisFrançais [41]
PortuguêsPortuguês [42]
DeutschDeutsch [43]
[20]
Dual Owner's Manual [37]
[44]
USAUSA [44]
[20]
Decoder Worksheet [44]
[45]
USAUSA [45]
MetricMetric [46]
EspañolEspañol [47]
ItalianoItaliano [48]
FrançaisFrançais [49]
PortuguêsPortuguês [50]
DeutschDeutsch [51]
TürkçeTürkçe [52]
PolskiPolski [53]
[20]
I-Core Owner's Manual [45]

Photos

[54]
USAUSA [54]
[20]
I-Core Dual Photos [54]

Specifications

[55]
USAUSA [55]
MetricMetric [56]
[20]
Dual Installation Detail - DWG [55]
[57]
USAUSA [57]
MetricMetric [58]
[20]
Dual Installation Detail - DXF [57]
[59]
USAUSA [59]
MetricMetric [60]
[20]
Dual Installation Detail - PDF [59]
[61]
USAUSA [61]
[20]
I-Core / Dual Written Specifications [61]

Video

[62]
USAUSA [62]
[20]
Hunter Dual Two-Wire Installation: 1 of 8 Introduction [62]
[63]
USAUSA [63]
[20]
Hunter Dual Two-Wire Installation: 2 of 8 Dual Grounding [63]
[64]
USAUSA [64]
[20]
Hunter Dual Two-Wire Installation: 3 of 8 Installing the Dual 48M Decoder Output Module [64]
[65]
USAUSA [65]
[20]
Hunter Dual Two-Wire Installation: 4 of 8 Dual Connecting Two-Wire Paths [65]
[66]
USAUSA [66]
[20]
Hunter Dual Two-Wire Installation: 5 of 8 Connecting Decoders to Valve Solenoids [66]
[67]
USAUSA [67]
[20]
Hunter Dual Two-Wire Installation: 6 of 8 Connecting DUAL-S Surge Suppressors [67]
[68]
USAUSA [68]
[20]
Hunter Dual Two-Wire Installation: 7 of 8 Tee-Splicing the Two-Wire Path [68]
[69]
USAUSA [69]
[20]
Hunter Dual Two-Wire Installation: 8 of 8 Programming with the ICD-HP Handheld Programmer [69]

View All Resources for This Product [70]

Support
TopicTitle [71]Rating [72]
FAQs, Installation ProceduresWhat are the grounding specifications on a Hunter DUAL system?

 >> Read More [73]

5
Educational, Installation Procedures, VideoHow do I program a DUAL decoder?

 >> Read More [74]

4.8
FAQs, TroubleshootingCan the ICD-HP program DUAL decoders?

 >> Read More [75]

5

Source URL (retrieved on 22/05/2013 - 12:33): http://www.hunterindustries.com/irrigation-product/controllers/dual?referer=&solrsort=is_rating%2520asc

Links:
[1] http://www.hunterindustries.com/node/669
[2] http://www.hunterindustries.com/node/662
[3] http://www.hunterindustries.com/node/663
[4] http://www.hunterindustries.com/node/666
[5] http://www.hunterindustries.com/node/667
[6] http://www.hunterindustries.com/node/29851
[7] http://www.hunterindustries.com/node/28016
[8] http://www.hunterindustries.com/node/28051
[9] http://www.hunterindustries.com/product/controllers/i-core
[10] http://www.hunterindustries.com/product/controllers/dual
[11] http://www.hunterindustries.com/product/controllers/acc
[12] http://www.hunterindustries.com/product/controllers/acc-99d-decoder
[13] http://www.hunterindustries.com/sites/default/files/BR_Dual_dom.pdf
[14] http://www.hunterindustries.com/sites/default/files/BR_Dual_em.pdf
[15] http://www.hunterindustries.com/sites/default/files/BR_Dual_SP.pdf
[16] http://www.hunterindustries.com/sites/default/files/BR_Dual_IT.pdf
[17] http://www.hunterindustries.com/sites/default/files/BR_Dual_FR.pdf
[18] http://www.hunterindustries.com/sites/default/files/BR_Dual_PT.pdf
[19] http://www.hunterindustries.com/sites/default/files/BR_Dual_GR.pdf
[20] http://www.hunterindustries.com/global
[21] http://www.hunterindustries.com/sites/default/files/PSCS_DUAL_dom.pdf
[22] http://www.hunterindustries.com/sites/default/files/DG_DecoderDesignGuide_dom.pdf
[23] http://www.hunterindustries.com/sites/default/files/DG_DecoderDesignGuide_em.pdf
[24] http://www.hunterindustries.com/sites/default/files/DG_DecoderDesignGuide_sp.pdf
[25] http://www.hunterindustries.com/sites/default/files/DG_DecoderDesignGuide_it.pdf
[26] http://www.hunterindustries.com/sites/default/files/DG_DecoderDesignGuide_fr.pdf
[27] http://www.hunterindustries.com/sites/default/files/DG_DecoderDesignGuide_gr.pdf
[28] http://www.hunterindustries.com/sites/default/files/dg_decoderdesignguide_tr.pdf
[29] http://www.hunterindustries.com/sites/default/files/BR_ICDHP_dom.pdf
[30] http://www.hunterindustries.com/sites/default/files/BR_ICDHP_em.pdf
[31] http://www.hunterindustries.com/sites/default/files/BR_ICDHP_SP.pdf
[32] http://www.hunterindustries.com/sites/default/files/BR_ICDHP_it.pdf
[33] http://www.hunterindustries.com/sites/default/files/BR_ICDHP_FR.pdf
[34] http://www.hunterindustries.com/sites/default/files/BR_ICDHP_PT.pdf
[35] http://www.hunterindustries.com/sites/default/files/BR_ICDHP_GR.pdf
[36] http://www.hunterindustries.com/sites/default/files/BR_ICD-HP_tk.pdf
[37] http://www.hunterindustries.com/sites/default/files/OM_Dual_dom.pdf
[38] http://www.hunterindustries.com/sites/default/files/OM_Dual_em.pdf
[39] http://www.hunterindustries.com/sites/default/files/OM_Dual_SP.pdf
[40] http://www.hunterindustries.com/sites/default/files/OM_Dual_IT.pdf
[41] http://www.hunterindustries.com/sites/default/files/OM_Dual_FR.pdf
[42] http://www.hunterindustries.com/sites/default/files/OM_Dual_PT.pdf
[43] http://www.hunterindustries.com/sites/default/files/OM_Dual_GR.pdf
[44] http://www.hunterindustries.com/sites/default/files/Decoder_Worksheet.pdf
[45] http://www.hunterindustries.com/sites/default/files/OM_ICORE_Dom.pdf
[46] http://www.hunterindustries.com/sites/default/files/OM_ICORE_em.pdf
[47] http://www.hunterindustries.com/sites/default/files/OM_ICore_SP.pdf
[48] http://www.hunterindustries.com/sites/default/files/OM_ICore_IT.pdf
[49] http://www.hunterindustries.com/sites/default/files/OM_ICore_FR.pdf
[50] http://www.hunterindustries.com/sites/default/files/OM_ICore_PT.pdf
[51] http://www.hunterindustries.com/sites/default/files/OM_ICore_GR.pdf
[52] http://www.hunterindustries.com/sites/default/files/om_icore_tr.pdf
[53] http://www.hunterindustries.com/sites/default/files/om_icore_po.pdf
[54] http://www.hunterindustries.com/sites/default/files/productimagepack_controller_i-core-dual.zip
[55] http://www.hunterindustries.com/sites/default/files/DualImperialDWG.zip
[56] http://www.hunterindustries.com/sites/default/files/DualMetricDWG.zip
[57] http://www.hunterindustries.com/sites/default/files/DUALImperialDXF.zip
[58] http://www.hunterindustries.com/sites/default/files/DualMetricDXF.zip
[59] http://www.hunterindustries.com/sites/default/files/DUALImperialPDF.zip
[60] http://www.hunterindustries.com/sites/default/files/DualMetricPDF.zip
[61] http://www.hunterindustries.com/sites/default/files/WS_ICore_DUAL.doc
[62] http://www.hunterindustries.com/media/3139/colorbox-ajax?iframe=true&amp;scrolling=no&amp;height=490&amp;width=660
[63] http://www.hunterindustries.com/media/3140/colorbox-ajax?iframe=true&amp;scrolling=no&amp;height=490&amp;width=660
[64] http://www.hunterindustries.com/media/3141/colorbox-ajax?iframe=true&amp;scrolling=no&amp;height=490&amp;width=660
[65] http://www.hunterindustries.com/media/3142/colorbox-ajax?iframe=true&amp;scrolling=no&amp;height=490&amp;width=660
[66] http://www.hunterindustries.com/media/3143/colorbox-ajax?iframe=true&amp;scrolling=no&amp;height=490&amp;width=660
[67] http://www.hunterindustries.com/media/3144/colorbox-ajax?iframe=true&amp;scrolling=no&amp;height=490&amp;width=660
[68] http://www.hunterindustries.com/media/3145/colorbox-ajax?iframe=true&amp;scrolling=no&amp;height=490&amp;width=660
[69] http://www.hunterindustries.com/media/3146/colorbox-ajax?iframe=true&amp;scrolling=no&amp;height=490&amp;width=660
[70] http://www.hunterindustries.com/resources?f%5B0%5D=im_field_related_products%3A243
[71] http://www.hunterindustries.com/print/irrigation-product/controllers/dual?referer=&amp;solrsort=sort_label%20asc#node_product_full_group_support_tab
[72] http://www.hunterindustries.com/print/irrigation-product/controllers/dual?referer=&amp;solrsort=is_rating%20asc#node_product_full_group_support_tab
[73] http://www.hunterindustries.com/support/what-are-grounding-specifications-hunter-dual-system
[74] http://www.hunterindustries.com/support/how-do-i-program-dual-decoder
[75] http://www.hunterindustries.com/support/can-icd-hp-program-dual-decoders