The commercial-grade ICV was built to work seamlessly with the most demanding systems. It boasts an array of reliable features like a fabric reinforced EPDM diaphragm and seat, and flow control. It can consistently operate at up to 220 PSI, and will continue working through difficult circumstances like high velocities, fluctuating flow rates, and challenging water conditions. In addition to its unmatched reliability, the ICV is also exceptionally easy to maintain. Its bonnet fasteners can be loosened and tightened using a variety of common contractor tools. A Filter Sentry option is also available for applications that involve dirty water. The Filter Sentry system keeps the valve free of debris found in reclaimed water or ponds. For the ultimate reliability in high pressure situations, the ICV is clearly the professional's ultimate choice.

 

Product Tabs

Features
  • Application: Commercial/municipal

  • Sizes: 1”, 1-1/2”, 2”, 3”

  • External and internal manual bleed allows quick and easy “at the valve” activation

  • Glass-filled nylon construction results in the highest pressure rating

  • Double-beaded diaphragm seal design for superior leak-free performance

  • Fabric reinforced EPDM diaphragm and EPDM seat ensure superior performance in all water conditions

  • Optional DC latching solenoids enable Hunter’s battery-powered controllers

  • Captive bonnet bolts provide hassle-free valve maintenance

  • Low flow capability allows for use with Hunter's micro irrigation products

  • Encapsulated 24 VAC solenoid with captive plunger for hassle-free service

  • Temperature rating: 150° F

  • Warranty period: 5 years

Flow Control [1]

Maximize efficiency and prolong the life of a system by fine tuning flow and pressure for each zone.

Filter Sentry™ [2]

The Filter Sentry scours the filter clean with a wiper that slides up and covers the entire screen when the valve opens. Even more, the wiper continues to scrub the filter's upper part during valve operation. The Filter Sentry can be added after the valve is installed as well.

Reclaimed Water Identification [3]

Violet tags and handles are an option for a clear, quick, and simple method of identifying the use of non-potable water.

Valve Models

PGV-101, PGV-ASV-100, PGV-100JT, PGV101JT

  • Reclaimed Water Handle P/N: 269205

PGV-151, PGV-201

  • Reclaimed Water Handle P/N: 607105

ICV100, ICV151, ICV201

  • Reclaimed Water Handle P/N: 561205

ICV301

  • Reclaimed Water Handle P/N: 515005

Accu-Sync™ Pressure Regulation [4]

Avoid sprinkler over-pressure conditions and experience significant water savings with Hunter's Accu-Sync pressure regulator. This option is available in adjustable pressure or fixed pressure models.

Models

ICV Models Chart

 

ICV-101G
Inlet Diameter: 1"

ICV-151G
Inlet Diameter: 1.5"

ICV-201G
Inlet Diameter: 2"

ICV-301
Inlet Diameter: 3"

Height 5-1/2" 7-1/8" 7-1/8" 10-3/4"
Length 4-3/4" 6-7/8" 6-7/8" 9-1/4"
Width 4" 5-1/2" 5-1/2" 7-3/8"

ICV Pressure Loss in PSI

GPM 1" 1½" 2 3" Globe 3" Angle
0.1 2.0        
0.5 2.0        
1 2.0        
5 2.5        
10 3.0        
15 3.0        
20 3.0 1.5      
30 9.0 1.5      
40 20.0 1.7 0.8    
50   2.2 1.2    
60   3.0 1.7    
75   3.9 2.4    
90   5.5 3.2    
100   7.0 4.2    
120   10.9 6.5    
135   12.7 7.9    
150   16.2 9.8 2.5 1.9
175     13.3 3.0 2.4
200     17.7 4.1 3.3
225       5.3 4.3
250       6.7 5.5
275       8.3 6.9
300       10.1 8.5

SPECIFICATION BUILDER

MODELS

INLET/OUTLET

OPTIONS
FACTORY INSTALLED

OPTIONS
USER INSTALLED

ICV-101G = 1" globe valve

(blank) = NPT threads

(blank) = No option
FS = Filter Sentry
DC = DC latching solenoid

 

(blank) = No option
R = Reclaimed water ID handle
CC = Solenoid conduit cover
DC = DC latching solenoid
AS-ADJ = Accu-Sync adjustable pressure regulator
AS-20 = Accu-Sync 20 PSI pressure regulator
AS-30 = Accu-Sync 30 PSI pressure regulator
AS-40 = Accu-Sync 40 PSI pressure regulator
AS-50 = Accu-Sync 50 PSI pressure regulator
AS-70 = Accu-Sync 70 PSI pressure regulator

ICV-151G = 1-1/2" globe valve
ICV-201G = 2" globe valve
ICV-301 = 3" globe/angle valve

EXAMPLES

ICV-101G

1" globe valve

ICV-151G - FS - R 1 ½" globe valve, Filter Sentry, and reclaimed water ID tag

ICV & IBV Comparison Chart

<< View SRV & PGV Valves [5]

Premium Valves That Can Conquer All
Low flow to high flow, clean water to dirty water, low pressure to high pressure, Hunter provides a valve option that can handle any situation for years to come.

[6]

[6]

[7]

[7]

  ICV [6] ICV Filter Sentry™ [6] IBV [7] IBV Filter Sentry™ [7]
QUICK SPECS
Size 1", 1½", 2", 3" 1", 1½", 2", 3" 1", 1½", 2", 3" 1", 1½", 2", 3"
Flow 0.1 to 300 GPM 0.1 to 300 GPM 0.1 to 300 GPM 0.1 to 300 GPM
FEATURES
Captive Bonnet Bolts    
EPDM Diaphragm and Seat Standard Standard Standard Standard
Warranty 5 Years 5 Years 5 Years 5 Years
ADVANCED FEATURES
Flow Control
Filter Sentry Field Installed Factory Installed Field Installed Factory Installed
ACCU-SYNC Capable
Reclaimed Water ID Handle Field Installed Factory Installed    
Reclaimed Water ID Tag Field Installed Factory Installed Field Installed Factory Installed
Applications
Residential      
Commericial
Potable water
Reclaimed water
Secondary water    
Pressure regulation
High pressure systems
Low pressure systems
High Temperature locations
Specifications

Operating Specifications

  • Flow rate:
    • ICV-101G: 0.1 to 40 GPM
    • ICV-151G: 20 to 135 GPM
    • ICV-201G: 40 to 150 GPM
    • ICV-301: 150 to 300 GPM
  • Recommended pressure range: 20 to 220 PSI

Solenoid Specifications

  • 24 VAC solenoid
    • 350 mA inrush, 190 mA holding, 60 HZ
    • 370 mA inrush, 210 mA holding, 50 HZ

Factory Installed Options

  • DC latching solenoid
  • Filter Sentry

User Installed Options

  • Solenoid conduit cover (P/N 464322)
  • DC latching solenoid (P/N 458200)
  • Accu-Sync pressure regulator
  • Reclaimed water ID handle for ICV101, 151, 201 (P/N 561205) and 301 (P/N 515005)
  • Reclaimed water ID Tag for all ICV valves (P/N 700392) (Included on Filter Sentry Models)
Resources

Literature

[8]
USAUSA [8]
MetricMetric [9]
EspañolEspañol [10]
ItalianoItaliano [11]
FrançaisFrançais [12]
DeutschDeutsch [13]
TürkçeTürkçe [14]
[15]
ICV Brochure [8]
[16]
USAUSA [16]
[15]
ICV Product Spec Cut Sheet [16]

Photos

[17]
USAUSA [17]
[15]
ICV Photos [17]

Specifications

[18]
USAUSA [18]
MetricMetric [19]
[15]
ICV Installation Detail - DWG [18]
[20]
USAUSA [20]
MetricMetric [21]
[15]
ICV Installation Detail - DXF [20]
[22]
USAUSA [22]
MetricMetric [23]
[15]
ICV Installation Detail - PDF [22]
[24]
USAUSA [24]
[15]
ICV Written Specification [24]
[25]
USAUSA [25]
[15]
Automatic Control Valves - Written Specifications - MasterSpec® [25]

Video

[26]
USAUSA [26]
[15]
Valve Series: Cleaning the Diaphragm on a Valve [26]
[27]
USAUSA [27]
[15]
Valve Series: Troubleshooting a Valve that is not Opening [27]
[28]
USAUSA [28]
[15]
Valve Series: Valve Operation [28]
Support
TopicTitlesort descending [29]Rating [30]
EducationalChoosing A Hunter Valve

 >> Read More [31]

2.65
FAQs, VideoCleaning Debris From An Irrigation Valve

 >> Read More [32]

2.3
FAQs, Troubleshooting, VideoHow do I manually open a valve?

 >> Read More [33]

5
FAQs, TroubleshootingHow do I manually open a zone control valve without using the controller?

 >> Read More [34]

5
FAQs, Installation Procedures, TroubleshootingHow does an irrigation valve work?

 >> Read More [35]

3.15
Adjustment, FAQs, TroubleshootingHow does the flow control knob on my Hunter valve work?

 >> Read More [36]

3.25
Educational, Installation ProceduresInstalling a Hunter Valve

 >> Read More [37]

4
FAQs, VideoWhat are my pressure regulating options for Hunter valves?

 >> Read More [38]

4.3
FAQs, Troubleshooting, VideoWhy does my irrigation system continue running after the controller is turned to OFF or unplugged?

 >> Read More [39]

4.5
FAQs, TroubleshootingWhy does my valve close slow?

 >> Read More [40]

3

View All Support Articles for This Product [41]


Source URL (retrieved on 19/05/2013 - 12:30): http://www.hunterindustries.com/irrigation-product/valves/icv?solrsort=sort_label%20asc

Links:
[1] http://www.hunterindustries.com/node/252
[2] http://www.hunterindustries.com/node/254
[3] http://www.hunterindustries.com/node/253
[4] http://www.hunterindustries.com/node/255
[5] http://www.hunterindustries.com/node/28081
[6] http://www.hunterindustries.com/product/valves/icv
[7] http://www.hunterindustries.com/product/valves/ibv
[8] http://www.hunterindustries.com/sites/default/files/BR_ICV_dom.pdf
[9] http://www.hunterindustries.com/sites/default/files/BR_ICV_em.pdf
[10] http://www.hunterindustries.com/sites/default/files/BR_ICV_sp.pdf
[11] http://www.hunterindustries.com/sites/default/files/BR_ICV_it.pdf
[12] http://www.hunterindustries.com/sites/default/files/BR_ICV_fr.pdf
[13] http://www.hunterindustries.com/sites/default/files/BR_ICV_gr.pdf
[14] http://www.hunterindustries.com/sites/default/files/BR_ICV_tk.pdf
[15] http://www.hunterindustries.com/global
[16] http://www.hunterindustries.com/sites/default/files/PSCS_ICV_dom.pdf
[17] http://www.hunterindustries.com/sites/default/files/productimagepack_valve_ICV.zip
[18] http://www.hunterindustries.com/sites/default/files/ICVImperialDWG.zip
[19] http://www.hunterindustries.com/sites/default/files/ICVMetricDWG.zip
[20] http://www.hunterindustries.com/sites/default/files/ICVImperialDXF.zip
[21] http://www.hunterindustries.com/sites/default/files/ICVMetricDXF.zip
[22] http://www.hunterindustries.com/sites/default/files/ICVImperialPDF.zip
[23] http://www.hunterindustries.com/sites/default/files/ICVMetricPDF.zip
[24] http://www.hunterindustries.com/sites/default/files/WS_ICV.doc
[25] http://www.hunterindustries.com/sites/default/files/MS_Automatic_Control_Valves.DOC
[26] http://www.hunterindustries.com/media/3116/colorbox-ajax?iframe=true&amp;scrolling=no&amp;height=490&amp;width=660
[27] http://www.hunterindustries.com/media/3118/colorbox-ajax?iframe=true&amp;scrolling=no&amp;height=490&amp;width=660
[28] http://www.hunterindustries.com/media/3115/colorbox-ajax?iframe=true&amp;scrolling=no&amp;height=490&amp;width=660
[29] http://www.hunterindustries.com/print/irrigation-product/valves/icv?solrsort=sort_label%20desc#node_product_full_group_support_tab
[30] http://www.hunterindustries.com/print/irrigation-product/valves/icv?solrsort=is_rating%20asc#node_product_full_group_support_tab
[31] http://www.hunterindustries.com/support/choosing-hunter-valve
[32] http://www.hunterindustries.com/support/cleaning-debris-irrigation-valve
[33] http://www.hunterindustries.com/support/how-do-i-manually-open-valve
[34] http://www.hunterindustries.com/support/how-do-i-manually-open-zone-control-valve-without-using-controller
[35] http://www.hunterindustries.com/support/how-does-irrigation-valve-work
[36] http://www.hunterindustries.com/support/how-does-flow-control-knob-my-hunter-valve-work
[37] http://www.hunterindustries.com/support/installing-hunter-valve
[38] http://www.hunterindustries.com/support/what-are-my-pressure-regulating-options-hunter-valves
[39] http://www.hunterindustries.com/support/why-does-my-irrigation-system-continue-running-after-controller-turned-or-unplugged
[40] http://www.hunterindustries.com/support/why-does-my-valve-close-slow
[41] http://www.hunterindustries.com/support?f%5B0%5D=im_field_related_products%3A283