Hunter Industries
Published on Hunter Industries (http://www.hunterindustries.com)

Home > Products > Products > Irrigation Products > Valves > PGV JAR-TOP

PGV JAR-TOP

PGV JAR-TOP

The Jar-Top Makes This Go-To Valve an Easy Choice with Simple Serviceability

For maximum in convenience, reliability, and ease of service in a residential valve, the PGV Jar-Top is the solution. With the PGV Jar-Top, it’s possible to service a Hunter valve without using any tools. Even with this ease-of-maintenance and operational simplicity, the PGV Jar-Top still delivers quality and performance to handle the demands of any residential system. Choose from a wide range of different configurations for specific installations that vary from region to region. All models feature durable, high-grade, corrosive and UV-resistant PVC construction, glass reinforced jarring and a rugged double-beaded, leak-proof diaphragm with support to prevent stress failure.

Product Tabs

Features
  • Application: Residential

  • Size: 1”

  • External and internal manual bleed allows quick and easy “at the valve” activation

  • Durable glass-filled nylon threaded bonnet ring allows easy access without tools

  • Double-beaded diaphragm seal design for superior leak-free performance

  • Optional DC latching solenoids enable Hunter’s battery-powered controllers

  • Low flow capability allows use of Hunter’s micro irrigation products

  • Encapsulated 24 VAC solenoid with captive plunger for hassle-free service

  • Temperature rating: 150° F

  • Warranty period: 2 years

Flow Control [1]

Maximize efficiency and prolong the life of a system by fine tuning flow and pressure for each zone.

Reclaimed Water Identification [2]

Violet tags and handles are an option for a clear, quick, and simple method of identifying the use of non-potable water.

Valve Models

PGV-101, PGV-ASV-100, PGV-100JT, PGV101JT

  • Reclaimed Water Handle P/N: 269205

PGV-151, PGV-201

  • Reclaimed Water Handle P/N: 607105

ICV100, ICV151, ICV201

  • Reclaimed Water Handle P/N: 561205

ICV301

  • Reclaimed Water Handle P/N: 515005

Accu-Sync™ Pressure Regulation [3]

Avoid sprinkler over-pressure conditions and experience significant water savings with Hunter's Accu-Sync pressure regulator. This option is available in adjustable pressure or fixed pressure models.

Models

PGV Jar-Top Models Chart

 

PGV-100JT - G
Inlet Diameter: 1"

PGV-101JT - G
Inlet Diameter: 1"

Height 5-1/2" 5-1/2"
Length 4-1/2" 4-1/2"
Width 3-1/4" 3-1/4"

PGV Jar-Top Pressure Loss in PSI
GPM 1"
1 1.1
5 1.9
10 1.9
15 1.6
20 3.3
30 9.0
35 16
40 20

SPECIFICATION BUILDER

MODELS

INLET/OUTLET

OPTIONS
FACTORY INSTALLED

OPTIONS
USER INSTALLED

PGV-100JT = 1" Globe jar-top valve, no flow control

G = Female
GS = Slip x slip
MM = 1" Male x 1" male
MB = 1" Male x 1" Barb
MB075 = 1" Male x 3/4" barb
MB125 = 1" Male x 1¼" barb

(blank) = No option

LS = Less solenoid
(only available on
101JT - G,
100JT - G,
101JT - GB,
100JT - GB)

DC = DC latching solenoid

(blank) = No option
R = Reclaimed water ID handle
(Excluding PGV100JT models)
CC = Solenoid conduit cover
DC = DC latching solenoid
AS-ADJ = Accu-Sync adjustable pressure regulator
AS-20 = Accu-Sync 20 PSI pressure regulator
AS-30 = Accu-Sync 30 PSI pressure regulator
AS-40 = Accu-Sync 40 PSI pressure regulator
AS-50 = Accu-Sync 50 PSI pressure regulator
AS-70 = Accu-Sync 70 PSI pressure regulator
PGV-101JT = 1" Globe jar-top valve, with flow control

EXAMPLES

PGV-101JT - G

1" Globe jar-top valve, with flow control, and 1" female

PGV-101JT - GS - R 1" Globe jar-top valve, with flow control, slip x slip, and reclaimed water ID handle
PGV-101JT - G - R 1" Globe jar-top valve, with flow control, 1" female, and reclaimed water ID handle
PGV-100JT - MB075 - DC 1" Globe jar-top valve, no flow control, with 1" male x ¾" barb, and DC latching solenoid

SRV & PGV Valve Comparison Chart

View ICV & IBV Valves >> [4]

Keep Residential Landscapes Running Smooth
Valves are the heart of an irrigation system. Hunter has assembled one of the broadest line-ups in the industry to suit any residential system.

[5]

[6]

[7]

[8]

  SRV [5] PGV Jar-Top [6] PGV [7] PGV-ASV [8]
QUICK SPECS
Size 1" 1" 1", 1½", 2" ¾", 1"
Flow (GPM) 1 to 40 0.2 to 40 0.2 to 150 0.2 to 40
FEATURES
Captive Bonnet Bolts
Warranty 2 Years 2 Years 2 Years 2 Years
ADVANCED FEATURES
Flow Control   Optional Optional
ACCU-SYNC Capable
Reclaimed Water ID Handle   Field Installed Field Installed Field Installed
Applications
Residential
Commericial      
Potable water
Pressure regulation
Low pressure systems
Specifications

Operating Specifications

  • Flow rate: 0.2 to 40 GPM
  • Recommended pressure range: 20 to 150 PSI

Solenoid Specifications

  • 24 VAC solenoid
    • 350 mA inrush, 190 mA holding, 60 cycles
    • 370 mA inrush, 210 mA holding, 50 cycles

Factory Installed Options

  • Valve without solenoid
  • DC latching solenoid

User Installed Options

  • Solenoid conduit cover (P/N 464322)
  • DC latching solenoid (P/N 458200)
  • Accu-Sync pressure regulator
  • Reclaimed water ID (P/N 269205)
Resources

Literature

[9]
USAUSA [9]
[10]
PGV Jar Top Brochure [9]

Photos

[11]
USAUSA [11]
[10]
PGV Jar Top Photos [11]

Specifications

[12]
USAUSA [12]
MetricMetric [13]
[10]
PGV Installation Detail - DWG [12]
[14]
USAUSA [14]
MetricMetric [15]
[10]
PGV Installation Detail - DXF [14]
[16]
USAUSA [16]
MetricMetric [17]
[10]
PGV Installation Detail - PDF [16]
[18]
USAUSA [18]
[10]
PGV Jar Top Written Specification [18]
[19]
USAUSA [19]
[10]
Automatic Control Valves - Written Specifications - MasterSpec® [19]
Support
TopicTitle [20]Ratingsort descending [21]
FAQs, VideoCleaning Debris From An Irrigation Valve

 >> Read More [22]

2.3
FAQs, TroubleshootingWhy does my valve close slow?

 >> Read More [23]

3
FAQs, Installation Procedures, TroubleshootingHow does an irrigation valve work?

 >> Read More [24]

3.15
Adjustment, FAQs, TroubleshootingHow does the flow control knob on my Hunter valve work?

 >> Read More [25]

3.25
FAQs, VideoWhat are my pressure regulating options for Hunter valves?

 >> Read More [26]

4.3
FAQs, Troubleshooting, VideoWhy does my irrigation system continue running after the controller is turned to OFF or unplugged?

 >> Read More [27]

4.5
FAQs, Troubleshooting, VideoWhy is my controller continuing to run after it's unplugged?

 >> Read More [28]

4.7
FAQs, Troubleshooting, VideoHow do I manually open a valve?

 >> Read More [29]

5

Source URL (retrieved on 21/05/2013 - 04:48): http://www.hunterindustries.com/irrigation-product/valves/pgv-jar-top?referer=&solrsort=is_rating%20asc

Links:
[1] http://www.hunterindustries.com/node/252
[2] http://www.hunterindustries.com/node/253
[3] http://www.hunterindustries.com/node/255
[4] http://www.hunterindustries.com/node/28066
[5] http://www.hunterindustries.com/product/valves/srv
[6] http://www.hunterindustries.com/product/valves/pgv-jar-top
[7] http://www.hunterindustries.com/product/valves/pgv
[8] http://www.hunterindustries.com/product/valves/pgv-asv
[9] http://www.hunterindustries.com/sites/default/files/BR_PGVJARTOP_dom.pdf
[10] http://www.hunterindustries.com/global
[11] http://www.hunterindustries.com/sites/default/files/productimagepack_valve_PGV-Jar_Top.zip
[12] http://www.hunterindustries.com/sites/default/files/PGVImperialDWG.zip
[13] http://www.hunterindustries.com/sites/default/files/PGVMetricDWG.zip
[14] http://www.hunterindustries.com/sites/default/files/PGVImperialDXF.zip
[15] http://www.hunterindustries.com/sites/default/files/PGVMetricDXF.zip
[16] http://www.hunterindustries.com/sites/default/files/PGVImperialPDF.zip
[17] http://www.hunterindustries.com/sites/default/files/PGVMetricPDF.zip
[18] http://www.hunterindustries.com/sites/default/files/WS_PGVJT.DOC
[19] http://www.hunterindustries.com/sites/default/files/MS_Automatic_Control_Valves.DOC
[20] http://www.hunterindustries.com/print/irrigation-product/valves/pgv-jar-top?referer=&solrsort=sort_label%20asc#node_product_full_group_support_tab
[21] http://www.hunterindustries.com/print/irrigation-product/valves/pgv-jar-top?referer=&solrsort=is_rating%20desc#node_product_full_group_support_tab
[22] http://www.hunterindustries.com/support/cleaning-debris-irrigation-valve
[23] http://www.hunterindustries.com/support/why-does-my-valve-close-slow
[24] http://www.hunterindustries.com/support/how-does-irrigation-valve-work
[25] http://www.hunterindustries.com/support/how-does-flow-control-knob-my-hunter-valve-work
[26] http://www.hunterindustries.com/support/what-are-my-pressure-regulating-options-hunter-valves
[27] http://www.hunterindustries.com/support/why-does-my-irrigation-system-continue-running-after-controller-turned-or-unplugged
[28] http://www.hunterindustries.com/support/why-my-controller-continuing-run-after-its-unplugged
[29] http://www.hunterindustries.com/support/how-do-i-manually-open-valve