Professional Grade Valves Ready for All System Sizes

This hard working, heavy-duty valve offers the best features of Hunter’s top-of-the-line valves. Built with enough durability to handle the rigors of most residential and light commercial sites, the PGV is available in an array of configurations. For smaller landscape applications, the PGV is available in four 1" body configurations: angle, globe, male x male, or male x barb design. In turn, each model is available in either a flow control or non-flow control version. For larger landscape applications, the PGV comes in both 1-1/2" and 2" globe/angle models (with flow control). All models feature durable high-grade construction and a rugged diaphragm with support to prevent stress failure.

Product Tabs

Features
  • Application (PGV-100): Residential

  • Application (PGV-101, 151, 201): Residential/light commercial

  • Sizes: 1", 1-1⁄2", 2"

  • External and internal manual bleed allows quick and easy “at the valve” activation

  • Double-beaded diaphragm seal design for superior leak-free performance

  • Optional: DC latching solenoids enable Hunter’s battery-powered controllers

  • Captive bonnet bolts provide hassle-free valve maintenance

  • Low flow capability allows use of Hunter’s micro-irrigation products

  • Encapsulated 24 VAC solenoid with captive plunger for hassle-free service

  • Temperature rating: 150° F

  • Warranty period: 2 years

Flow Control [1]

Maximize efficiency and prolong the life of a system by fine tuning flow and pressure for each zone.

Accu-Sync™ Pressure Regulation [2]

Avoid sprinkler over-pressure conditions and experience significant water savings with Hunter's Accu-Sync pressure regulator. This option is available in adjustable pressure or fixed pressure models.

Reclaimed Water Identification [3]

Violet tags and handles are an option for a clear, quick, and simple method of identifying the use of non-potable water.

Valve Models

PGV-101, PGV-ASV-100, PGV-100JT, PGV101JT

  • Reclaimed Water Handle P/N: 269205

PGV-151, PGV-201

  • Reclaimed Water Handle P/N: 607105

ICV100, ICV151, ICV201

  • Reclaimed Water Handle P/N: 561205

ICV301

  • Reclaimed Water Handle P/N: 515005
Models

PGV Model Chart

 

PGV-100G
Inlet Diameter: 1"

PGV-101G
Inlet Diameter: 1"

PGV-151
Inlet Diameter: 1.5"

PGV-201
Inlet Diameter: 2"

Height 5" 5" 7 ½" 8"
Length 4 ½" 4 ½" 5 ¾" 6 ¾"
Width 2 ½" 2 ½" 4 ½" 5 ¼"

PGV Pressure Loss in PSI

GPM 1" Globe 1" Angle 1½" Globe 1 ½" Angle 2" Globe 2" Angle
1 1.1 1        
5 1.9 1        
10 1.9 1        
15 1.6 1        
20 3.3 2 3 3 1 1
30 9.1 9 3 3 1 2
35 16 16 3 3 2 2
40 20 21 3 3 2 2
50     4 3.5 1 1
60     5 4 2 2
80     5.5 4.5 3 2
100     9 8 5 3
120     11.5 10.5 6 5
135         8 7
150         10 9

SPECIFICATION BUILDER

MODELS

INLET/OUTLET

OPTIONS
FACTORY INSTALLED

OPTIONS
USER INSTALLED

PGV-100G = 1" Globe valve, no flow control

(blank) = 1" Female
S = 1" Slip x 1" slip (excludes PGV-151
and PGV-201)

(blank) = No option
DC = DC latching solenoid
LS = Valve without solenoid

R = Reclaimed water ID handle
(except PGV-100)

CC = Solenoid conduit cover
DC = DC latching solenoid
AS-ADJ = Accu-Sync adjustable pressure regulator
AS-20 = Accu-Sync 20 PSI pressure regulator
AS-30 = Accu-Sync 30 PSI pressure regulator
AS-40 = Accu-Sync 40 PSI pressure regulator
AS-50 = Accu-Sync 50 PSI pressure regulator
AS-70 = Accu-Sync 70 PSI pressure regulator

PGV-101G = 1" Globe valve, with flow control
PGV-100A = 1" Angle valve, no flow control
PGV-101A = 1" Angle valve, with flow control
PGV-151 = 1½" Globe/angle valve, with flow control
PGV-201 = 2" Globe/angle valve, with flow control
PGV-100 = 1" Globe valve, no flow control MB = 1" Male x 1" Barb
MB125 = 1" Male x 1¼" barb
MM = 1" Male x 1" male

 
PGV-101 = 1" Globe valve, with flow control

EXAMPLES

PGV-101G - S - DC

1" Globe valve, with flow control, slip x slip, and DC latching solenoid

PGV-100 - MB - AS 1" Globe valve, no flow control, male thread x 1" barb, and Accu-Sync™ pressure regulator
PGV-151 - DC - R 1 ½" Globe/angle valve, with flow control, DC latching solenoid, and reclaimed water ID handle

SRV & PGV Valve Comparison Chart

View ICV & IBV Valves >> [4]

Keep Residential Landscapes Running Smooth
Valves are the heart of an irrigation system. Hunter has assembled one of the broadest line-ups in the industry to suit any residential system.

[5]

[6]

[7]

[8]

  SRV [5] PGV Jar-Top [6] PGV [7] PGV-ASV [8]
QUICK SPECS
Size 1" 1" 1", 1½", 2" ¾", 1"
Flow (GPM) 1 to 40 0.2 to 40 0.2 to 150 0.2 to 40
FEATURES
Captive Bonnet Bolts
Warranty 2 Years 2 Years 2 Years 2 Years
ADVANCED FEATURES
Flow Control   Optional Optional
ACCU-SYNC Capable
Reclaimed Water ID Handle   Field Installed Field Installed Field Installed
Applications
Residential
Commericial      
Potable water
Pressure regulation
Low pressure systems
Specifications

Operating Specifications

  • Flow rate:
    • PGV-100: 0.2 to 40 GPM
    • PGV-101: 0.2 to 40 GPM
    • PGV-151: 20 to 120 GPM
    • PGV-201: 20 to 150 GPM
  • Recommended pressure range: 20 to 150 PSI

Solenoid Specifications

  • 24 VAC solenoid
    • 350 mA inrush, 190 mA holding, 60 HZ
    • 370 mA inrush, 210 mA holding, 50 HZ

Factory Installed Options

  • Valve without solenoid
  • DC latching solenoid

User Installed Options

  • Solenoid conduit cover (P/N 464322)
  • DC latching solenoid (P/N 458200)
  • Accu-Sync pressure regulator
  • Reclaimed water ID handle for PGV-101 models (P/N 269205) and PGV-151/201 models (P/N 607105)
Resources

Literature

[9]
USAUSA [9]
MetricMetric [10]
EspañolEspañol [11]
ItalianoItaliano [12]
FrançaisFrançais [13]
DeutschDeutsch [14]
[15]
PGV Brochure [9]

Photos

[16]
USAUSA [16]
[15]
PGV Photos [16]

Specifications

[17]
USAUSA [17]
MetricMetric [18]
[15]
PGV Installation Detail - DWG [17]
[19]
USAUSA [19]
MetricMetric [20]
[15]
PGV Installation Detail - DXF [19]
[21]
USAUSA [21]
MetricMetric [22]
[15]
PGV Installation Detail - PDF [21]
[23]
USAUSA [23]
[15]
PGV Written Specification [23]
[24]
USAUSA [24]
[15]
Automatic Control Valves - Written Specifications - MasterSpec® [24]

Video

[25]
USAUSA [25]
[15]
Valve Series: Cleaning the Diaphragm on a Valve [25]
[26]
USAUSA [26]
[15]
Valve Series: Troubleshooting a Valve that is not Opening [26]
[27]
USAUSA [27]
[15]
Valve Series: Valve Operation [27]
Support
TopicTitle [28]Rating [29]
FAQs, Troubleshooting, VideoHow do I manually open a valve?

 >> Read More [30]

5
FAQs, TroubleshootingHow do I manually open a zone control valve without using the controller?

 >> Read More [31]

5
FAQs, Troubleshooting, VideoWhy is my controller continuing to run after it's unplugged?

 >> Read More [32]

4.7
FAQs, Troubleshooting, VideoWhy does my irrigation system continue running after the controller is turned to OFF or unplugged?

 >> Read More [33]

4.5
FAQs, VideoWhat are my pressure regulating options for Hunter valves?

 >> Read More [34]

4.3
FAQs, Installation ProceduresIs pressure regulation necessary when using drip irrigation?

 >> Read More [35]

4
Educational, Installation ProceduresInstalling a Hunter Valve

 >> Read More [36]

4
Adjustment, FAQs, TroubleshootingHow does the flow control knob on my Hunter valve work?

 >> Read More [37]

3.25
FAQs, Installation Procedures, TroubleshootingHow does an irrigation valve work?

 >> Read More [38]

3.15
FAQs, TroubleshootingWhy does my valve close slow?

 >> Read More [39]

3

View All Support Articles for This Product [40]


Source URL (retrieved on 25/05/2013 - 21:07): http://www.hunterindustries.com/irrigation-product/valves/pgv?referer=

Links:
[1] http://www.hunterindustries.com/node/252
[2] http://www.hunterindustries.com/node/255
[3] http://www.hunterindustries.com/node/253
[4] http://www.hunterindustries.com/node/28066
[5] http://www.hunterindustries.com/product/valves/srv
[6] http://www.hunterindustries.com/product/valves/pgv-jar-top
[7] http://www.hunterindustries.com/product/valves/pgv
[8] http://www.hunterindustries.com/product/valves/pgv-asv
[9] http://www.hunterindustries.com/sites/default/files/BR_PGV_dom.pdf
[10] http://www.hunterindustries.com/sites/default/files/BR_PGV_em.pdf
[11] http://www.hunterindustries.com/sites/default/files/BR_PGV_sp.pdf
[12] http://www.hunterindustries.com/sites/default/files/BR_PGV_IT.pdf
[13] http://www.hunterindustries.com/sites/default/files/BR_PGV_fr.pdf
[14] http://www.hunterindustries.com/sites/default/files/BR_PGV_gr.pdf
[15] http://www.hunterindustries.com/global
[16] http://www.hunterindustries.com/sites/default/files/productimagepack_valve_PGV.zip
[17] http://www.hunterindustries.com/sites/default/files/PGVImperialDWG.zip
[18] http://www.hunterindustries.com/sites/default/files/PGVMetricDWG.zip
[19] http://www.hunterindustries.com/sites/default/files/PGVImperialDXF.zip
[20] http://www.hunterindustries.com/sites/default/files/PGVMetricDXF.zip
[21] http://www.hunterindustries.com/sites/default/files/PGVImperialPDF.zip
[22] http://www.hunterindustries.com/sites/default/files/PGVMetricPDF.zip
[23] http://www.hunterindustries.com/sites/default/files/WS_PGV.DOC
[24] http://www.hunterindustries.com/sites/default/files/MS_Automatic_Control_Valves.DOC
[25] http://www.hunterindustries.com/media/3116/colorbox-ajax?iframe=true&scrolling=no&height=490&width=660
[26] http://www.hunterindustries.com/media/3118/colorbox-ajax?iframe=true&scrolling=no&height=490&width=660
[27] http://www.hunterindustries.com/media/3115/colorbox-ajax?iframe=true&scrolling=no&height=490&width=660
[28] http://www.hunterindustries.com/print/irrigation-product/valves/pgv?referer=&solrsort=sort_label%20asc#node_product_full_group_support_tab
[29] http://www.hunterindustries.com/print/irrigation-product/valves/pgv?referer=&solrsort=is_rating%20asc#node_product_full_group_support_tab
[30] http://www.hunterindustries.com/support/how-do-i-manually-open-valve
[31] http://www.hunterindustries.com/support/how-do-i-manually-open-zone-control-valve-without-using-controller
[32] http://www.hunterindustries.com/support/why-my-controller-continuing-run-after-its-unplugged
[33] http://www.hunterindustries.com/support/why-does-my-irrigation-system-continue-running-after-controller-turned-or-unplugged
[34] http://www.hunterindustries.com/support/what-are-my-pressure-regulating-options-hunter-valves
[35] http://www.hunterindustries.com/support/pressure-regulation-necessary-when-using-drip-irrigation
[36] http://www.hunterindustries.com/support/installing-hunter-valve
[37] http://www.hunterindustries.com/support/how-does-flow-control-knob-my-hunter-valve-work
[38] http://www.hunterindustries.com/support/how-does-irrigation-valve-work
[39] http://www.hunterindustries.com/support/why-does-my-valve-close-slow
[40] http://www.hunterindustries.com/support?f%5B0%5D=im_field_related_products%3A280