The I-90-ON is now compatible with Hunter PGP nozzles, the opposing nozzles and the mid and short range nozzles can now be outfitted with normal PGP nozzles.

Now that there are multiple options and configurations of nozzle pairings, each nozzle's precip rate will have to be taken into consideration. A total precip rate for all nozzles will no longer be accurate.

[3]

 

PGP Red Nozzle Performance Data

 

PGP Red Nozzle Rack

PGP Red Nozzle
Performance Data (P/N 130900)

Nozzle Pressure
(PSI)
Radius
(ft.)
Flow
(GPM)
Precip in/hr

1

30

28

0.5

0.12

0.14

40

29

0.6

0.14

0.16

50

29

0.7

0.16

0.19

60

30

0.8

0.17

0.20

2

30

29

0.7

0.16

0.19

40

30

0.8

0.17

0.20

50

30

0.9

0.19

0.22

60

31

1.0

0.20

0.23

3

30

30

0.9

0.19

0.22

40

31

1.0

0.20

0.23

50

31

1.2

0.24

0.28

60

32

1.3

0.24

0.28

4

30

32

1.2

0.23

0.26

40

33

1.4

0.25

0.29

50

34

1.6

0.27

0.31

60

34

1.8

0.30

0.35

5

30

32

1.6

0.30

0.35

40

36

1.8

0.27

0.31

50

38

2.0

0.27

0.31

60

38

2.2

0.29

0.34

6

30

34

2.0

0.33

0.38

40

36

2.4

0.36

0.41

50

38

2.7

0.36

0.42

60

38

2.9

0.39

0.45

7

30

34

2.6

0.43

0.50

40

38

3.0

0.40

0.46

50

40

3.4

0.41

0.47

60

40

3.7

0.45

0.51

8

30

37

3.2

0.45

0.52

40

39

3.7

0.47

0.54

50

41

3.9

0.45

0.52

60

42

4.6

0.50

0.58

9

30

38

3.6

0.48

0.55

40

41

4.3

0.49

0.57

50

44

5.2

0.52

0.60

60

45

5.5

0.52

0.60

10

40

44

6.0

0.60

0.69

50

46

6.8

0.62

0.71

60

47

7.6

0.66

0.76

70

49

8.2

0.66

0.76

11

40

46

8.0

0.73

0.84

50

48

8.9

0.74

0.86

60

50

9.8

0.75

0.87

70

51

10.5

0.78

0.90

12

40

46

10.5

0.96

1.10

50

48

11.9

0.99

1.15

60

50

12.7

0.98

1.13

70

52

14.1

1.00

1.16

Note: All preciptation rates calculated for 180 degree operation.
For the precipitation rate for a 360 degree sprinkler, divide by 2.

I90-36V Performance Data

I-90 Nozzle Rack

Nozzle Pressure
PSI
Radius
ft.
Flow
GPM
Precip in/hr

25

Lt. Blue

80 73 30.5 0.55 0.64
90 75 32.4 0.55 0.64
100 76 34.3 0.57 0.66
110 78 36.5 0.58 0.67
120 79 38.4 0.59 0.68
33

Gray

80 77 36.3 0.59 0.68
90 78 38.4 0.61 0.70
100 80 40.6 0.61 0.71
110 81 42.7 0.63 0.72
120 82 44.9 0.64 0.74
38

Red

80 80 40.6 0.61 0.71
90 82 42.9 0.61 0.71
100 83 45.3 0.63 0.73
110 85 47.7 0.64 0.73
120 86 50.2 0.65 0.75
43

Dk. Brown

80 83 46.2 0.65 0.75
90 84 48.6 0.66 0.77
100 85 50.9 0.68 0.78
110 86 53.4 0.69 0.80
120 87 55.9 0.71 0.82
48

Dk. Green

80 86 49.6 0.65 0.75
90 89 52.5 0.64 0.74
100 90 54.8 0.65 0.75
110 91 57.3 0.67 0.77
120 92 59.5 0.68 0.78
53

Dk. Blue*

80 89 54.2 0.66 0.76
90 90 56.7 0.67 0.78
100 92 59.2 0.67 0.78
110 93 61.7 0.69 0.79
120 94 64.2 0.70 0.81
63

Black

80 92 63.2 0.72 0.83
90 94 65.9 0.72 0.83
100 96 69.4 0.72 0.84
110 97 72.0 0.74 0.85
120 98 74.9 0.75 0.87
73

Orange

80 96 72.1 0.75 0.87
90 98 75.0 0.75 0.87
100 99 77.8 0.76 0.88
110 102 80.5 0.74 0.86
120 103 83.3 0.76 0.87

* Factory-installed nozzle


Precipitation rates for 36V models are calculated for 360-degree operation. All triangular rates are equilateral.


For low angle nozzle performance, reduce radius by 15%.


Complies to ASAE standard.

PGP Blue Standard Nozzle Performance Data

PGP Nozzle Rack

PGP Blue Standard Nozzle
Performance Data (P/N 665300)

Nozzle Pressure
(PSI)
Radius
(ft.)
Flow
(GPM)
Precip in/hr

1.5

25

29

1.2

0.27

0.32

35

31

1.4

0.28

0.32

45

31

1.5

0.30

0.35

55

32

1.8

0.34

0.39

65

32

1.9

0.36

0.41

2.0

25

33

1.4

0.25

0.29

35

33

1.7

0.30

0.35

45

34

2.0

0.33

0.38

55

34

2.1

0.35

0.40

65

34

2.3

0.38

0.44

2.5

25

33

1.7

0.30

0.35

35

35

2.1

0.33

0.38

45

35

2.5

0.39

0.45

55

35

2.6

0.41

0.47

65

35

2.9

0.46

0.53

3.0

25

35

2.2

0.35

0.40

35

36

2.7

0.40

0.46

45

38

3.0

0.40

0.46

55

39

3.4

0.43

0.50

65

39

3.7

0.47

0.54

4.0

25

37

3.0

0.42

0.49

35

39

3.5

0.44

0.51

45

40

4.0

0.48

0.56

55

41

4.5

0.52

0.60

65

41

4.8

0.55

0.63

5.0

25

37

3.7

0.52

0.60

35

39

4.5

0.57

0.66

45

42

5.0

0.55

0.63

55

42

5.7

0.62

0.72

65

42

6.2

0.68

0.78

6.0

25

38

4.3

0.57

0.66

35

40

5.6

0.67

0.78

45

43

6.0

0.62

0.72

55

44

6.7

0.67

0.77

65

44

7.3

0.73

0.84

8.0

25

37

6.0

0.84

0.97

35

41

7.0

0.80

0.93

45

44

8.0

0.80

0.92

55

46

9.0

0.82

0.95

65

46

9.8

0.89

1.03

Note: All preciptation rates calculated for 180 degree operation.
For the precipitation rate for a 360 degree sprinkler, divide by 2.

Rate this Article: 
Average: 4 (2 votes)

Still not finding the answers?

View more support documents [4]

Hunter Technical Support experts are available to answer your question(s) about Hunter products and their usage, simply click on the contact button below to submit an email request.

[5]

Related Links


Source URL (retrieved on 19/05/2013 - 19:34): http://www.hunterindustries.com/support/how-do-you-calculate-precipitation-rates-i-90-rotor-opposing-nozzles

Links:
[1] http://www.hunterindustries.com/product-line/rotors
[2] http://www.hunterindustries.com/irrigation-product/rotors/i-90
[3] http://www.hunterindustries.com/sites/default/files/ts_i90_adj_install-3_0.jpg
[4] http://www.hunterindustries.com/support
[5] http://www.hunterindustries.com/support/email_support/email