The I-90-ON is now compatible with Hunter PGP nozzles, the opposing nozzles and the mid and short range nozzles can now be outfitted with normal PGP nozzles. Now that there are multiple options and configurations of nozzle pairings, each nozzle's precip rate will have to be taken into consideration. A total precip rate for all nozzles will no longer be accurate. |
PGP Red Nozzle Performance Data
|
PGP Red Nozzle
|
|||||
|---|---|---|---|---|---|
| Nozzle | Pressure (PSI) |
Radius (ft.) |
Flow (GPM) |
Precip in/hr | |
|
|
|||||
1 |
30 |
28 |
0.5 |
0.12 |
0.14 |
|
40 |
29 |
0.6 |
0.14 |
0.16 |
|
|
50 |
29 |
0.7 |
0.16 |
0.19 |
|
|
60 |
30 |
0.8 |
0.17 |
0.20 |
|
2 |
30 |
29 |
0.7 |
0.16 |
0.19 |
|
40 |
30 |
0.8 |
0.17 |
0.20 |
|
|
50 |
30 |
0.9 |
0.19 |
0.22 |
|
|
60 |
31 |
1.0 |
0.20 |
0.23 |
|
3 |
30 |
30 |
0.9 |
0.19 |
0.22 |
|
40 |
31 |
1.0 |
0.20 |
0.23 |
|
|
50 |
31 |
1.2 |
0.24 |
0.28 |
|
|
60 |
32 |
1.3 |
0.24 |
0.28 |
|
4 |
30 |
32 |
1.2 |
0.23 |
0.26 |
|
40 |
33 |
1.4 |
0.25 |
0.29 |
|
|
50 |
34 |
1.6 |
0.27 |
0.31 |
|
|
60 |
34 |
1.8 |
0.30 |
0.35 |
|
5 |
30 |
32 |
1.6 |
0.30 |
0.35 |
|
40 |
36 |
1.8 |
0.27 |
0.31 |
|
|
50 |
38 |
2.0 |
0.27 |
0.31 |
|
|
60 |
38 |
2.2 |
0.29 |
0.34 |
|
6 |
30 |
34 |
2.0 |
0.33 |
0.38 |
|
40 |
36 |
2.4 |
0.36 |
0.41 |
|
|
50 |
38 |
2.7 |
0.36 |
0.42 |
|
|
60 |
38 |
2.9 |
0.39 |
0.45 |
|
7 |
30 |
34 |
2.6 |
0.43 |
0.50 |
|
40 |
38 |
3.0 |
0.40 |
0.46 |
|
|
50 |
40 |
3.4 |
0.41 |
0.47 |
|
|
60 |
40 |
3.7 |
0.45 |
0.51 |
|
8 |
30 |
37 |
3.2 |
0.45 |
0.52 |
|
40 |
39 |
3.7 |
0.47 |
0.54 |
|
|
50 |
41 |
3.9 |
0.45 |
0.52 |
|
|
60 |
42 |
4.6 |
0.50 |
0.58 |
|
9 |
30 |
38 |
3.6 |
0.48 |
0.55 |
|
40 |
41 |
4.3 |
0.49 |
0.57 |
|
|
50 |
44 |
5.2 |
0.52 |
0.60 |
|
|
60 |
45 |
5.5 |
0.52 |
0.60 |
|
10 |
40 |
44 |
6.0 |
0.60 |
0.69 |
|
50 |
46 |
6.8 |
0.62 |
0.71 |
|
|
60 |
47 |
7.6 |
0.66 |
0.76 |
|
|
70 |
49 |
8.2 |
0.66 |
0.76 |
|
11 |
40 |
46 |
8.0 |
0.73 |
0.84 |
|
50 |
48 |
8.9 |
0.74 |
0.86 |
|
|
60 |
50 |
9.8 |
0.75 |
0.87 |
|
|
70 |
51 |
10.5 |
0.78 |
0.90 |
|
12 |
40 |
46 |
10.5 |
0.96 |
1.10 |
|
50 |
48 |
11.9 |
0.99 |
1.15 |
|
|
60 |
50 |
12.7 |
0.98 |
1.13 |
|
|
70 |
52 |
14.1 |
1.00 |
1.16 |
|
|
Note: All preciptation rates calculated for 180 degree operation. |
|||||
I90-36V Performance Data
| Nozzle | Pressure PSI |
Radius ft. |
Flow GPM |
Precip in/hr | |
|
|
|||||
25Lt. Blue |
80 | 73 | 30.5 | 0.55 | 0.64 |
| 90 | 75 | 32.4 | 0.55 | 0.64 | |
| 100 | 76 | 34.3 | 0.57 | 0.66 | |
| 110 | 78 | 36.5 | 0.58 | 0.67 | |
| 120 | 79 | 38.4 | 0.59 | 0.68 | |
33Gray |
80 | 77 | 36.3 | 0.59 | 0.68 |
| 90 | 78 | 38.4 | 0.61 | 0.70 | |
| 100 | 80 | 40.6 | 0.61 | 0.71 | |
| 110 | 81 | 42.7 | 0.63 | 0.72 | |
| 120 | 82 | 44.9 | 0.64 | 0.74 | |
38Red |
80 | 80 | 40.6 | 0.61 | 0.71 |
| 90 | 82 | 42.9 | 0.61 | 0.71 | |
| 100 | 83 | 45.3 | 0.63 | 0.73 | |
| 110 | 85 | 47.7 | 0.64 | 0.73 | |
| 120 | 86 | 50.2 | 0.65 | 0.75 | |
43Dk. Brown |
80 | 83 | 46.2 | 0.65 | 0.75 |
| 90 | 84 | 48.6 | 0.66 | 0.77 | |
| 100 | 85 | 50.9 | 0.68 | 0.78 | |
| 110 | 86 | 53.4 | 0.69 | 0.80 | |
| 120 | 87 | 55.9 | 0.71 | 0.82 | |
48Dk. Green |
80 | 86 | 49.6 | 0.65 | 0.75 |
| 90 | 89 | 52.5 | 0.64 | 0.74 | |
| 100 | 90 | 54.8 | 0.65 | 0.75 | |
| 110 | 91 | 57.3 | 0.67 | 0.77 | |
| 120 | 92 | 59.5 | 0.68 | 0.78 | |
53Dk. Blue* |
80 | 89 | 54.2 | 0.66 | 0.76 |
| 90 | 90 | 56.7 | 0.67 | 0.78 | |
| 100 | 92 | 59.2 | 0.67 | 0.78 | |
| 110 | 93 | 61.7 | 0.69 | 0.79 | |
| 120 | 94 | 64.2 | 0.70 | 0.81 | |
63Black |
80 | 92 | 63.2 | 0.72 | 0.83 |
| 90 | 94 | 65.9 | 0.72 | 0.83 | |
| 100 | 96 | 69.4 | 0.72 | 0.84 | |
| 110 | 97 | 72.0 | 0.74 | 0.85 | |
| 120 | 98 | 74.9 | 0.75 | 0.87 | |
73Orange |
80 | 96 | 72.1 | 0.75 | 0.87 |
| 90 | 98 | 75.0 | 0.75 | 0.87 | |
| 100 | 99 | 77.8 | 0.76 | 0.88 | |
| 110 | 102 | 80.5 | 0.74 | 0.86 | |
| 120 | 103 | 83.3 | 0.76 | 0.87 | |
|
* Factory-installed nozzle Precipitation rates for 36V models are calculated for 360-degree operation. All triangular rates are equilateral. For low angle nozzle performance, reduce radius by 15%. Complies to ASAE standard. |
|||||
PGP Blue Standard Nozzle Performance Data
PGP Blue Standard Nozzle
|
|||||
|---|---|---|---|---|---|
| Nozzle | Pressure (PSI) |
Radius (ft.) |
Flow (GPM) |
Precip in/hr | |
|
|
|||||
| 1.5 |
25 |
29 |
1.2 |
0.27 |
0.32 |
|
35 |
31 |
1.4 |
0.28 |
0.32 |
|
|
45 |
31 |
1.5 |
0.30 |
0.35 |
|
|
55 |
32 |
1.8 |
0.34 |
0.39 |
|
|
65 |
32 |
1.9 |
0.36 |
0.41 |
|
| 2.0 |
25 |
33 |
1.4 |
0.25 |
0.29 |
|
35 |
33 |
1.7 |
0.30 |
0.35 |
|
|
45 |
34 |
2.0 |
0.33 |
0.38 |
|
|
55 |
34 |
2.1 |
0.35 |
0.40 |
|
|
65 |
34 |
2.3 |
0.38 |
0.44 |
|
| 2.5 |
25 |
33 |
1.7 |
0.30 |
0.35 |
|
35 |
35 |
2.1 |
0.33 |
0.38 |
|
|
45 |
35 |
2.5 |
0.39 |
0.45 |
|
|
55 |
35 |
2.6 |
0.41 |
0.47 |
|
|
65 |
35 |
2.9 |
0.46 |
0.53 |
|
| 3.0 |
25 |
35 |
2.2 |
0.35 |
0.40 |
|
35 |
36 |
2.7 |
0.40 |
0.46 |
|
|
45 |
38 |
3.0 |
0.40 |
0.46 |
|
|
55 |
39 |
3.4 |
0.43 |
0.50 |
|
|
65 |
39 |
3.7 |
0.47 |
0.54 |
|
| 4.0 |
25 |
37 |
3.0 |
0.42 |
0.49 |
|
35 |
39 |
3.5 |
0.44 |
0.51 |
|
|
45 |
40 |
4.0 |
0.48 |
0.56 |
|
|
55 |
41 |
4.5 |
0.52 |
0.60 |
|
|
65 |
41 |
4.8 |
0.55 |
0.63 |
|
| 5.0 |
25 |
37 |
3.7 |
0.52 |
0.60 |
|
35 |
39 |
4.5 |
0.57 |
0.66 |
|
|
45 |
42 |
5.0 |
0.55 |
0.63 |
|
|
55 |
42 |
5.7 |
0.62 |
0.72 |
|
|
65 |
42 |
6.2 |
0.68 |
0.78 |
|
| 6.0 |
25 |
38 |
4.3 |
0.57 |
0.66 |
|
35 |
40 |
5.6 |
0.67 |
0.78 |
|
|
45 |
43 |
6.0 |
0.62 |
0.72 |
|
|
55 |
44 |
6.7 |
0.67 |
0.77 |
|
|
65 |
44 |
7.3 |
0.73 |
0.84 |
|
| 8.0 |
25 |
37 |
6.0 |
0.84 |
0.97 |
|
35 |
41 |
7.0 |
0.80 |
0.93 |
|
|
45 |
44 |
8.0 |
0.80 |
0.92 |
|
|
55 |
46 |
9.0 |
0.82 |
0.95 |
|
|
65 |
46 |
9.8 |
0.89 |
1.03 |
|
|
Note: All preciptation rates calculated for 180 degree operation. |
|||||