Centralus - Alarms

The controller will store up to 250 alarm logs, with date and time, beginning with the most recent alarm. When the Text Message Alerts are set up, you can receive one of the messages listed below for each model controller.

NOTE: Centralus will not send more than one text alert per controller in a 24-hour period.

ACC2 - Alarms
  • On Critical Alarms Only
    • stationSizeIsZero: Not detecting any station or decoder modules. The Station size is 0.
    • Low voltage fault: The primary AC power to the controller is too low (below 105 VAC).
    • RTC (Real Time Clock): There can be a fault in the clock, and/or the CR2032 battery is dead or missing.
    • mainSafeFlowZoneFlowAlarmDetected: Overflow/Underflow/No Flow detected with a MainSafe.
    • decoderModuleOverloaded: The decoder module's maximum current load has exceeded (1800mA on 1.2Hz).
    • stationFaultDetected: Overcurrent detected for a station that exceeded 800mA.
    • PMVFaultDetected: Overcurrent detected for a Pump or MasterValve that exceeded 800mA.
    • weatherSensorCommsFaultDetected: No communication with a sensor.
    • maximumTransformerCurrentExceeded: Overcurrent detected on the internal transformer. Exceeding 1Amp on 50/60 Hz
    • CANBusFaultDetected: Facepack will not communicate with any module (exception is flow module). 
    • weatherSensorAlarmDetected: Sensor status has changed from inactive to active.
    • NWWViolationDetected: A No Water Window schedule is active.
    • sensorDecoderFault: The sensor decoder is not programmed correctly or is not detected on the two-wire path.
    • poweroutage: This fault is generated when the power is restored.
ICC2 - Alarms
  • On Critical Alarms Only
  • When the sensor is active
  • On dial position change
  • When a programmable day off is active