ACC2 - Program Rules

PROGRAM RULES customizes each program for setting up a NO WATER WINDOW or STATION DELAY.

  • Ignore Calendar Days Off: Check the box if the program should be allowed to run on Calendar Days Off that apply to other programs.
  • No Water Window (Start and End): Enter start and end times for the portion of the day during which automatic irrigation is never allowed. Automatic programs will never be allowed to run during this period, although Manual operations will be allowed. If a program is suspended by a No Water Window, it will be logged as an alarm, for corrective action.
  • Station Delay (Delay Between Stations): Sets an interval between each station in a program. This can be used for slow-closing valves, recharging pressure tanks, etc. During the delay, the P/MV output will continue running for 15 seconds, unless this is adjusted in the Devices, P/MV Operation screen.
1

Select the lower right soft key to view the MAIN MENU.

2

Press the scroll wheel to select. Turn the scroll wheel to the right to view the PROGRAM RULES menu. Press the scroll wheel to select.

3

Press the scroll wheel to select. Turn the scroll wheel to the right to select the correct PROGRAM. Press the scroll wheel to select.

4

Turn the scroll wheel to the right to highlight NO WATER WINDOW START. Select a time to START the Window. Press the scroll wheel to select.

5

Turn the scroll wheel to the right to highlight NO WATER WINDOW END. Select a time to END the Window. Press the scroll wheel to select.

6

If a STATION DELAY is desired, turn the scroll wheel to the right to highlight the STATION DELAY entry. Select a time. Press the scroll wheel to select. Select the soft key to edit the next program or HOME to exit.