Hunter I-Core Dual controller and decoder system
DUAL for I-Core
DUAL for I-Core
DUAL for I-Core

DUAL® for I-Core™

Save materials and labour by adding this optional plug-in module to upgrade conventional I-Core systems to two-wire control.
Number of Stations 1 to 48
Type Modular Decoder

Easy Installation: The Dual decoder module easily plugs into the I-Core controller, converting it to two-wire/ decoder control. Up to 3 two-wire paths can be wired to the controller, for maximum design flexibility.

Connections Made Easy: Color-coded connections simplify installation with any standard 24 VAC irrigation solenoids.

7,500 Feet Each Direction: Wire up to 7,500 feet of 12 AWG or 5,000 feet of 14 AWG.

Models

Model Description Add to List
DUAL-1 DUAL Decoder for use with I-Core Controller, 1-station +
DUAL-2 DUAL Decoder for use with I-Core Controller, 2-station +
DUAL-S DUAL Decoder for use with I-Core Controller, surge arrestor +
DUAL48M DUAL Decoder Output Module for use with I-Core Controller, up to 48 stations +

Choose: user-installed options

Model Description Add to List
DUAL48M

DUAL Decoder Output Module for use with I-Core Controller, up to 48 stations

+
DUAL-1

DUAL Decoder for use with I-Core Controller, 1-station

+
DUAL-2

DUAL Decoder for use with I-Core Controller, 2-station

+
DUAL-S

DUAL Decoder for use with I-Core Controller, surge arrestor

+
DECSTAKE10

Universal Decoder Stake Kit, 10 per carton

+
Model Description Add to List
SOLAR-SYNC-SEN

Solar Sync Sensor, wired, includes 7.5 m wire and gutter mount

+
WSS-SEN

Solar Sync Sensor, wireless, includes receiver and gutter mount

+
RAIN-CLIK

Rain-Clik Sensor, wired rain sensor with Quick Response Technology shutoff, includes 7.5 m wire

+
WR-CLIK

Wireless Rain-Clik Sensor Kit with Quick Response Technology shutoff; includes sensor, receiver, and aluminum mount

+
MINI-CLIK

Mini-Clik Sensor, wired rain sensor, adjustable from ⅛" to ¾" of rainfall, includes 7.5 m wire and aluminum mount

+
FREEZE-CLIK

Freeze-Clik Sensor, wired, shuts off system at 3ºC

+
WIND-CLIK

Wind-Clik Sensor, adjustable wind control, high-wind shutdown from12 to 35 mph, 24 VAC, 5 A

+
FLOW-CLIK

Flow sensor kit includes sensor and programming module; sensor requires FCT fitting for pipe installation

+
SOIL-CLIK

Soil-Clik Sensor, soil moisture sensor system; includes sensor and receiver module

+
WFS

Wireless Flow Sensor Kit; use with I-Core, ACC, and ACC2 Controllers, 900 MHz

+
HFS

Flow-Sync Sensor, use with ACC2, ICC2, and legacy ACC and I-Core Controllers; requires FCT fitting for pipe installation

+
DUAL® for I-Core™
DUAL® for I-Core™
DUAL® for I-Core™
User installed options

Contact your local distributor for product availability and ordering.

Specifications

Dual Model Specifications

  • Maximum recommended distance, decoder to solenoid: 30 m
  • Maximum distance to decoder:
    • 2 mm2 wire path: 1.5 km
    • 3.3 mm2 wire path: 2.3 km
  • Approvals: UL, cUL, FCC, CE, RCM
  • Decoder rating: IP68 submersible
  • Warranty period: 2 years

Videos

Hunter Dual Two-Wire Installation: Tee-Splicing the Two-Wire Path 7 of 8

Video 7 of 8 installation of the Hunter Dual decoder two-wire system with I-Core controller. Tee-Splicing the two-wire path.

Hunter Dual Two-Wire Installation: Programming with the ICD-HP Handheld Programmer 8 of 8

Video 8 of 8 of installation of the Hunter Dual decoder two-wire system with I-Core controller. Programming with the ICD-HP handheld programmer.

Hunter Dual Two-Wire Installation: Introduction 1 of 8

Introduction to installation of the Hunter Dual decoder two-wire system with I-Core controller.

Hunter Dual Two-Wire Installation: Installing the Dual 48M Decoder Output Module 3 of 8

Video 3 of 4 installation of the Hunter Dual decoder two-wire system with I-Core controller.

Hunter Dual Two-Wire Installation: Dual Grounding 2 of 8

Video 2 of 8 installation of the Hunter Dual decoder two-wire system with I-Core controller.

Hunter Dual Two-Wire Installation: Dual Connecting Two-Wire Paths 4 of 8

Video 4 of 8 installation of the Hunter Dual decoder two-wire system with I-Core controller. This section will go over connecting 2-Wire paths.

All Product Videos

Features

Designed to bring the convenience and efficiency of two-wire technology to all, the DUAL system can operate up to 48 zones via a single pair of wires, at distances up to 7,500 feet (2.3 km). All 48 zones can be installed on a single path, or divided over multiple paths to take advantage of pipe trenches. Since it’s I-Core-compatible, system operators still receive advanced features and benefits like flow monitoring, quick system overview access, a factory-installed SmartPort®, six language capabilities, and a bold, graphic display. DUAL Decoders are available in one and two-station versions. 

Key Benefits

3 separate two-wire paths provide flexibility in system design and installation
1- and 2-station decoders available for use with a variety of valve manifolds
Field-programmable decoders do not require serial numbers
Decoders can be programmed before installation at the DUAL48M interface
Wireless programming with ICD-HP allows for decoder programming or re-programming after installation to the two-wire path
DUAL-S external surge protection module provides additional protection
DUAL48M output module displays decoder programming, operation, and diagnostic information for assistance with maintenance and troubleshooting
DUAL48M may be installed with conventional modules for hybrid operations
Solenoid finder feature aids in locating decoders and valves in the field

Advanced Features

The DUAL Decoder System starts with the I-Core controller and adds the benefits of a two-wire decoder system.

Field programmability means no lengthy serial numbers to enter in the controller, and no time lost re-programming decoder assignments after a controller change. Each decoder is programmed with its actual station (valve) numbers for simplicity and reliability. Decoders may be re-programmed at any time if desired.

All Hunter decoders feature wireless programming and diagnostic access from the ICD-HP handheld programmer. Patented technology allows programming and diagnostics through the housing of the decoder, without removing a single wire or waterproof connector. Program, operate, and diagnose decoders in-place in field valve boxes.

Hunter’s unique jacketed decoder wire is high-strength, durable, sunlight protected, and part of the integrated lightning management system. Twisted pair conductors are color-coded for decoder system connections, and the outer jackets can be uniquely color-coded to organize field wire runs and assist in future wire tracking. Tough PE (polyethylene) jacket protects wire from sharp rocks and exposure to UV rays. Available in two wire sizes for different length requirements.

Each Hunter decoder includes 2 DBRY-6 waterproof connector kits, UL listed to 600V direct burial. Only the best connectors will do in the critical two-wire path, but there is no need to go shopping for them separately. Suitable for all sizes of ID Wire connections.

Documents

  • All
  • Manuals
  • Marketing
  • Specifications
  • CAD Details
  • Replacement Parts
Show all documents

Studio Photos

Image
Title:
DUAL
File:
dual.jpg
Classification:
Studio
Product Line:
Controllers
Keywords:
product
,
controller
,
i-core
,
dual
,
station decoder
,
surge arrestor
,
DUAL-S
,
DUAL-1
,
DUAL-2
,
family
Image Page

Download Image

Medium Original
By clicking download, you agree to our terms and conditions.

Photo Usage Disclaimer

Disclaimer: It is illegal to reproduce Hunter photographs or other copyrighted material without the express written permission of the company. When used and/or reproduced, photos must be accompanied by the credit line: "Photo courtesy of Hunter Industries Incorporated." Hunter photos may not be used in association with copy, logos, or other graphic elements that represent other manufacturers' products. If you are using Hunter photos to create any type of print or graphic piece or on a website, you must send a copy of your intended use to creative@hunterindustries.com. Hunter must approve the design prior to final production.

All images must be accompanied by the credit line "Photo courtesy of Hunter Industries Incorporated." The credit line must appear adjacent to the photo.

Close
Image
Title:
DUAL-1
File:
dual_dsc_0318_rt.jpg
Classification:
Studio
Product Line:
Controllers
Keywords:
product
,
controller
,
i-core
,
dual
,
DUAL-1
,
station decoder
Image Page

Download Image

Medium Original
By clicking download, you agree to our terms and conditions.

Photo Usage Disclaimer

Disclaimer: It is illegal to reproduce Hunter photographs or other copyrighted material without the express written permission of the company. When used and/or reproduced, photos must be accompanied by the credit line: "Photo courtesy of Hunter Industries Incorporated." Hunter photos may not be used in association with copy, logos, or other graphic elements that represent other manufacturers' products. If you are using Hunter photos to create any type of print or graphic piece or on a website, you must send a copy of your intended use to creative@hunterindustries.com. Hunter must approve the design prior to final production.

All images must be accompanied by the credit line "Photo courtesy of Hunter Industries Incorporated." The credit line must appear adjacent to the photo.

Close
Image
Title:
DUAL-2
File:
dual_dsc_0317_rt.jpg
Classification:
Studio
Product Line:
Controllers
Keywords:
product
,
controller
,
i-core
,
dual
,
DUAL-2
,
station decoder
Image Page

Download Image

Medium Original
By clicking download, you agree to our terms and conditions.

Photo Usage Disclaimer

Disclaimer: It is illegal to reproduce Hunter photographs or other copyrighted material without the express written permission of the company. When used and/or reproduced, photos must be accompanied by the credit line: "Photo courtesy of Hunter Industries Incorporated." Hunter photos may not be used in association with copy, logos, or other graphic elements that represent other manufacturers' products. If you are using Hunter photos to create any type of print or graphic piece or on a website, you must send a copy of your intended use to creative@hunterindustries.com. Hunter must approve the design prior to final production.

All images must be accompanied by the credit line "Photo courtesy of Hunter Industries Incorporated." The credit line must appear adjacent to the photo.

Close
Image
Title:
DUAL-S
File:
dual_dsc_0316_rt.jpg
Classification:
Studio
Product Line:
Controllers
Keywords:
product
,
controller
,
i-core
,
dual
,
DUAL-S
,
surge arrestor
Image Page

Download Image

Medium Original
By clicking download, you agree to our terms and conditions.

Photo Usage Disclaimer

Disclaimer: It is illegal to reproduce Hunter photographs or other copyrighted material without the express written permission of the company. When used and/or reproduced, photos must be accompanied by the credit line: "Photo courtesy of Hunter Industries Incorporated." Hunter photos may not be used in association with copy, logos, or other graphic elements that represent other manufacturers' products. If you are using Hunter photos to create any type of print or graphic piece or on a website, you must send a copy of your intended use to creative@hunterindustries.com. Hunter must approve the design prior to final production.

All images must be accompanied by the credit line "Photo courtesy of Hunter Industries Incorporated." The credit line must appear adjacent to the photo.

Close
Image
Title:
DUAL48M
File:
dual_dsc_0335_rt.jpg
Classification:
Studio
Product Line:
Controllers
Keywords:
product
,
controller
,
i-core
,
dual
,
decoder module
,
DUAL48M
Image Page

Download Image

Medium Original
By clicking download, you agree to our terms and conditions.

Photo Usage Disclaimer

Disclaimer: It is illegal to reproduce Hunter photographs or other copyrighted material without the express written permission of the company. When used and/or reproduced, photos must be accompanied by the credit line: "Photo courtesy of Hunter Industries Incorporated." Hunter photos may not be used in association with copy, logos, or other graphic elements that represent other manufacturers' products. If you are using Hunter photos to create any type of print or graphic piece or on a website, you must send a copy of your intended use to creative@hunterindustries.com. Hunter must approve the design prior to final production.

All images must be accompanied by the credit line "Photo courtesy of Hunter Industries Incorporated." The credit line must appear adjacent to the photo.

Close
Image
Title:
Dual decoder module
File:
dual_decoder_module_002rt.jpg
Classification:
Studio
Product Line:
Controllers
Keywords:
product
,
controller
,
i-core
,
dual
,
decoder module
,
DUAL48M
Image Page

Download Image

Medium Original
By clicking download, you agree to our terms and conditions.

Photo Usage Disclaimer

Disclaimer: It is illegal to reproduce Hunter photographs or other copyrighted material without the express written permission of the company. When used and/or reproduced, photos must be accompanied by the credit line: "Photo courtesy of Hunter Industries Incorporated." Hunter photos may not be used in association with copy, logos, or other graphic elements that represent other manufacturers' products. If you are using Hunter photos to create any type of print or graphic piece or on a website, you must send a copy of your intended use to creative@hunterindustries.com. Hunter must approve the design prior to final production.

All images must be accompanied by the credit line "Photo courtesy of Hunter Industries Incorporated." The credit line must appear adjacent to the photo.

Close