These tables are designed for quick reference and are set up to provide maximum wire runs, given the information at the bottom of the table. Maximum one-way distance in feet between controller and valve heavy-duty solenoid: 24 VAC, 350 mA inrush current, 190 mA holding current, 60 Hz; 370 mA inrush current, 210 mA holding current, 50 Hz. The tables represent a single active solenoid. The wire distances should be halved with two solenoids operating simultaneously on the same wires.
Ground Wire | Control Wire (FT) | |||||
---|---|---|---|---|---|---|
18 AWG | 16 AWG | 14 AWG | 12 AWG | 10 AWG | 8 AWG | |
18 AWG | 850 | 1040 | 1210 | 1350 | 1460 | 1540 |
16 AWG | 1040 | 1340 | 1650 | 1920 | 2150 | 2330 |
14 AWG | 1210 | 1650 | 2150 | 2630 | 3080 | 3450 |
12 AWG | 1350 | 1920 | 2630 | 3390 | 4170 | 4880 |
10 AWG | 1460 | 2150 | 3080 | 4170 | 5400 | 6670 |
8 AWG | 1540 | 2330 | 3450 | 4880 | 6670 | 8700 |
Ground Wire | Control Wire (mm²) | |||||
---|---|---|---|---|---|---|
0.5 mm² | 1.0 mm² | 1.5 mm² | 2.5 mm² | 4.0 mm² | 6.0 mm² | |
0.5 mm² | 140 | 190 | 210 | 235 | 250 | 260 |
1.0 mm² | 190 | 290 | 335 | 415 | 465 | 495 |
1.5 mm² | 208 | 335 | 397 | 515 | 595 | 647 |
2.5 mm² | 235 | 415 | 515 | 730 | 900 | 1030 |
4.0 mm² | 250 | 465 | 595 | 900 | 1175 | 1405 |
6.0 mm² | 260 | 495 | 647 | 1030 | 1405 | 1745 |