I-90-36V Nozzle Performance Data
Nozzle Pressure Radius Flow Precip in/hr
  PSI ft GPM
25 
Lt. Blue
80 73 30.5 0.55 0.64
90 75 32.4 0.55 0.64
100 76 34.3 0.57 0.66
110 78 36.5 0.58 0.67
33 
Grey
80 77 36.3 0.59 0.68
90 78 38.4 0.61 0.7
100 80 40.6 0.61 0.71
110 81 42.7 0.63 0.72
38 
Red
80 80 40.6 0.61 0.71
90 82 42.9 0.61 0.71
100 83 45.3 0.63 0.73
110 85 47.7 0.64 0.73
43 
Dk. Brown
80 83 46.2 0.65 0.75
90 84 48.6 0.66 0.77
100 85 50.9 0.68 0.78
110 86 53.4 0.69 0.8
48 
Dk. Green
80 86 49.6 0.65 0.75
90 89 52.5 0.64 0.74
100 90 54.8 0.65 0.75
110 91 57.3 0.67 0.77
53 
Dk. Blue*
80 89 54.2 0.66 0.76
90 90 56.7 0.67 0.78
100 92 59.2 0.67 0.78
110 93 61.7 0.69 0.79
120 94 64.2 0.7 0.81
63 
Black
80 92 63.2 0.72 0.83
90 94 65.9 0.72 0.83
100 96 69.4 0.72 0.84
110 97 72 0.74 0.85
120 98 74.9 0.75 0.87
73 
Orange
80 96 72.1 0.75 0.87
90 98 75 0.75 0.87
100 99 77.8 0.76 0.88
110 102 80.5 0.74 0.86
120 103 83.3 0.76 0.87

* Factory installed nozzle.

Notes:
Precipitation rates for 36V models are calculated for 360-degree operation. All triangular rates are equilateral. For low angle nozzle performance, reduce radius by 15%. Complies to ASAE standard.