Valves - Maximum Wire Distance Between Controller and Valves

Below is a chart indicating the maximum wire runs that can be used
when installing Hunter AC solenoids and valves.

Valve Wire Sizing (Maximum One-Way Distance in Feet Between Controller and Valve)
Ground Wire Size Control Wire (ft)
 
18 AWG
16 AWG
14 AWG
12 AWG
10 AWG
8 AWG
6 AWG
18 AWG
850
1040
1210
1350
1460
1540
1590
16 AWG
1040
1340
1650
1920
2150
2330
2440
14 AWG
1210
1650
2150
2630
3080
3450
3700
12 AWG
1350
1920
2630
3390
4170
4880
5400
10 AWG
1460
2150
3080
4170
5400
6670
7690
8 AWG
1540
2330
3450
4880
6670
8700
10530
6 AWG
1590
2440
3700
5400
7690
10530
13330

 

Below are two charts indicating the maximum wire runs that can be used when operating Hunter DC Latching solenoids when using the XC HybridNODE, and NODE-BT controller models.

XC Hybrid Wire Length (Controller to Valve)
Wire Size Maximum Distance*
 
Feet
18 AWG
550
16 AWG
870
14 AWG
1380
12 AWG
2200
* Using Hunter DC Latching Solenoids
NODE AND NODE-BTWire Length (Controller to Valve)
Wire Size Maximum Distance*
 
Feet
18 AWG
100
* Using Hunter DC Latching Solenoids