Flow-Clik®
Models
Specifications
Operating Specifications
- Recommended pressure range: 0 to 220 PSI
- Current draw (24 VAC): 0.025 A
- Switching current: 2 A maximum
- Sensor wiring: 2 x direct burial, 18 AWG or greater, color-coded or marked for polarity, up to 1,000' from the programming module
- Programmable start up delay: 0 to 300 seconds (allows for system hydraulics to stabilize and prevents false flow readings)
- Programmable interrupt period: 5 to 60 minutes (or option to reset manually)
- Warranty period: 5 years
User-Installed Options
- FCT fittings for 1" to 4" pipe diameters
Features
A ruptured pipe or broken sprinkler left undetected can result in substantial landscape damage. Plants and ground cover can be flooded, slopes can be eroded, and hundreds of gallons of water can be wasted. Hunter created The Flow-Clik flow sensor is used to guard against these damages in the event of a rupture. The Flow-Clik can be programmed at a specified level of flow. It will shut down irrigation if it detects a flow rate higher than the programmed limit. Therefore, the amount of water loss and system damage is substantially reduced in the event of catastrophic high-flow scenarios.
Key Benefits
Charts
Pipe Diameter | Operating range (GPM) | |
---|---|---|
Minimum | Suggested maximum* | |
1" | 2 | 17 |
1 1/2" | 5 | 35 |
2" | 10 | 55 |
3" | 28 | 120 |
4" | 34 | 195 |
* Good design practice dictates the maximum flow not to exceed 5 ft./sec. Suggested maximum flow is based upon Class 200 IPS plastic pipe.
Flow-Sync Diameter | Operating range (GPM) | |
---|---|---|
Minimum | Suggested Maximum* | |
1" | 2 | 17 |
1.5" | 5 | 35 |
2" | 10 | 55 |
3" | 28 | 120 |
4" | 34 | 195 |
Notes:
* Good design practice dictates the maximum flow not to exceed 5 ft./sec. Suggested maximum flow is based upon Class 200 IPS plastic pipe