STEP ONE | STEP TWO |
---|---|
The nozzle is retained in the nozzle housing by a setscrew. To remove the nozzle, back out the setscrew so that the nozzle will clear. | Rotate the nozzle housing to place the diffuser yoke at its lowest position in order to provide clearance. |
STEP THREE | |
Grasp a nozzle tab with pliers and pull to remove. |
STEP ONE | STEP TWO |
---|---|
The nozzle is retained in the nozzle housing by a setscrew. | To remove the nozzle, first slide the diffuser pins to the extreme left, from the viewer's perspective, past the black stop post. |
All Models: Place the replacement nozzle in the housing. Press firmly to fully seat the nozzle so that it clears the retaining setscrew. Run the setscrew down to retain the nozzle, taking care not to run it down so far as to interfere with the nozzle stream. For I-60-ADS models, ensure the diffuser pins are placed back in line with the nozzle after the new nozzle is installed.
Visually check for proper installation of nozzles and setscrews.
Arc Adjustment
All I-60-ADS adjustable arc sprinklers are preset at approximately 180º. Sprinklers may be adjusted with water on or off. It is recommended that initial adjustment be made before installation.
|