Earth Ground Connection (Lightning Protection)
- Insert copper wire from earth ground hardware, and tighten screw in front.
- Minimum 10 AWG (5mm2) wire to earth ground hardware.
- Add copper-clad steel ground rods and/or plates sufficient to achieve 10Ω or less resistance at a minimum 8' (2.5 m) away from controller.
120V Wiring
Transformer Wire | Power Source | ||||
---|---|---|---|---|---|
1 | Brown | 230V (Not Used) | - | - | - |
2 | Black | 120V Hot | 5 | Black | 120V Hot |
3 | Blue | Neutral | 6 | White | Neutral |
4 | Green | Ground | 7 | Green | Ground |
230V Wiring
Transformer Wire | Power Source | ||||
---|---|---|---|---|---|
1 | Black | (Not Used) | - | - | - |
2 | Brown | 230V Hot | 5 | Brown | 230V Hot |
3 | Blue | Neutral | 6 | Blue or White | Neutral |
4 | Green | Ground | 7 | Green | Ground |
Still need help? We're here.