Support
ACC2 Support

ACC2 Decoder - Devices Menu

Devices allows setup of common external devices that the controller can use. The functions in the Devices menu are covered in more detail in other sections.

 

P/MV Operation

Set the Location for the P/MV (terminals on the controller power supply board, or the decoder output module if using decoder control). Set the Style, Normally Closed or Normally Open, for the Pump/Master Valve outputs. Change Location, if the P/MV is assigned to a decoder instead of a controller terminal. Pumps should always be set to Normally Closed to prevent damage. The P/MV Delay sets how long the P/MV will remain active if a station pauses, such as during the delay between stations. P/MV setup is covered in detail in the Pump/Master Valve section.

 

Flow Sensors

Flow Sensor setup is covered in detail in the Basic Programming, Sensors, and Flow Sensors section.

 

Solar Sync

Solar Sync setup is covered in detail in the Basic Programming, Sensors, and Solar Sync section.

 

Clik Sensors

Clik sensor setup is covered in detail in the Basic Programming, Sensors, and Clik Sensors section. Hunter sensors are normally-closed, and open when an alarm is active. The sensor inputs can be changed to normally-open (close on alarm) when used with other devices.

 

Sensor Response

Sensor Response is covered in detail in the Basic Programming, Sensors, and Flow Sensors section. A sensor response setting is required for any sensor to be able to shut off any program in the controller.