The NO NETWORK CARD PRESENT message could appear on your Network Info screen if the module was removed, then reinstalled. Also, a zero could display for the IP number. Use the steps below to check your current connection status.

USA

The WIRE TEST Feature will activate a 24 VAC-60 Hz frequency on all output modules and their two-wire paths, to allow wire tracking and fault finding with a standard AC current clamp meter. This is a common diagnostic technique to find shorts to earth ground. The AC current will drop sharply between two points on the wire path if a short circuit or fault to earth is between them. When troubleshooting is finished, press the soft key again to turn off the 60 Hz wire test mode.

USA

The communication module connection to the ACC2 facepack changed, effective with a facepack manufacturing date code May 2022 and later. The new facepack now has a separate communication connection on the rear of the facepack. The 1st Generation units have the connection directly in the module slot on the bottom of the facepack.

USA

Once the CELLKIT is installed in an ICC2 Controller and powered on, it is ready for connection to the internet. If you need to check on your CONNECTION STATUS or set up your own SIM configuration, download the free CELLKIT App from the App Store or Google Play, then follow the steps below.

NOTE: If using the Cellular (Hunter Provided Sim), the CELLKIT app is not required for any type of setup.

USA

The word USED displayed on the Pro-C Controller represents a landscape lighting station that was assigned. Once a start time is assigned to program L1, it turns station 1 from an irrigation station to a lighting station (same for L2 and L3). As a result, when creating programs for irrigation A, B, or C, station 1 will show USED since L1 has been assigned a start time. All irrigation stations will be wired using the next available station(s). Learn more 

USA

The HYDRAULIC SUMMARY is a report of exactly how the controller hydraulics are set up at the moment. It shows the connections of all flow-related objects, from MainSafe zones (if applicable), Flow Zones, Flow Sensors, P/MVs, to individual stations.

USA

LEARNING FLOW is an important step in the Flow Monitor setup (unless the MainSafe™ option is enabled) process.

  • Flow learning will only test stations that already have a Run Time in a program.
  • Flow learning will cancel all other irrigation, automatic and manual until the learning is complete. 
  • Flow cannot be learned while other stations are running for other reasons.
USA

FLOW TOTALS are total amounts of water consumed over a specified time period. They may also be viewed at different levels, depending on how the controller is configured. Total Flow is counted by the Flow Zone, individual flow sensor, and MainSafe (if applicable).

USA

The CYCLE & SOAK feature allows you to split a station’s runtime into shorter watering periods. The shorter watering periods will help prevent runoff in situations like slopes or tight soils. It is recommended that the CYCLE time is less than the station’s watering time, and the SOAK time for the water to be absorbed. The total number of cycles is determined by taking the total programmed station run time and dividing it by the CYCLE time (e.g., see chart below).

USA

The ACC2 Controller allows you to connect up to three CLIK SENSORS. These sensor inputs are already configured as Normally Closed, but this can be changed for other types of contact closure sensor inputs to Normally Open.