Instaladores - Page 4

The word USED displayed on the Pro-C Controller represents a landscape lighting station that was assigned. Once a start time is assigned to program L1, it turns station 1 from an irrigation station to a lighting station (same for L2 and L3). As a result, when creating programs for irrigation A, B, or C, station 1 will show USED since L1 has been assigned a start time. All irrigation stations will be wired using the next available station(s). Learn more 

USA

About this event

Instalação de um Sistema de Irrigação Comercial por 2 cabos.

Webinar: https://event.on24.com/wcc/r/3631727/0F42A9756EFC747FC77B549777CB28FD.

About this event

Instalación de un Sistema de Riego Comercial por 2 cables

Webinar: https://event.on24.com/wcc/r/3627913/38881C6B825D598EBEE194BB3A0EB882

  • 15:00 PM- 16:00 P.M. - Mexico
  • 18:00 - 19:00 P.M. - Chile
  • 18:00 - 19:00 P.M. - Buenos Aires/Montevideo
  • 18:00 - 19:00 P.M. - Uruguay

The HYDRAULIC SUMMARY is a report of exactly how the controller hydraulics are set up at the moment. It shows the connections of all flow-related objects, from MainSafe zones (if applicable), Flow Zones, Flow Sensors, P/MVs, to individual stations.

USA

LEARNING FLOW is an important step in the Flow Monitor setup (unless the MainSafe™ option is enabled) process.

  • Flow learning will only test stations that already have a Run Time in a program.
  • Flow learning will cancel all other irrigation, automatic and manual until the learning is complete. 
  • Flow cannot be learned while other stations are running for other reasons.
USA

FLOW TOTALS are total amounts of water consumed over a specified time period. They may also be viewed at different levels, depending on how the controller is configured. Total Flow is counted by the Flow Zone, individual flow sensor, and MainSafe (if applicable).

USA

The CYCLE & SOAK feature allows you to split a station’s runtime into shorter watering periods. The shorter watering periods will help prevent runoff in situations like slopes or tight soils. It is recommended that the CYCLE time is less than the station’s watering time, and the SOAK time for the water to be absorbed. The total number of cycles is determined by taking the total programmed station run time and dividing it by the CYCLE time (e.g., see chart below).

USA

About this event

Riego Residencial en 10 Pasos

Webinar: https://event.on24.com/wcc/r/3593379/4FFC5DE1D0B7EA529C2782CDBCC8EAAB

  • 15:00 PM- 16:00 P.M. - Mexico
  • 18:00 - 19:00 P.M. - Chile
  • 18:00 - 19:00 P.M. - Buenos Aires/Montevideo
  • 18:00 - 19:00 P.M. - Uruguay

About this event

Irrigação Residencial em 10 passos.

Webinar: https://event.on24.com/wcc/r/3601513/7923B19116CFE4FADCC068E610425648.

The ACC2 Controller allows you to connect up to three CLIK SENSORS. These sensor inputs are already configured as Normally Closed, but this can be changed for other types of contact closure sensor inputs to Normally Open.

USA

Pages