We recommend that a qualified licensed contractor perform this type of winterization method. The blowout method utilizes an air compressor with a cubic foot per minute (CFM) rating of 80-100 for any mainline of 2" or less. The compressor is attached to the mainline via a quick coupler, hose bib, or other type connection, which is located beyond the backflow device. Compressed air should not be blown through any backflow or flow meter device. For additional winterization procedures, we highly recommend contacting the local dealer for the most common local practices.

USA

Hunter warrants the Wireless Rain-Clik (WR-CLIK) for five years. If a defect in a Hunter product is discovered during the applicable warranty period, Hunter will repair or replace, at its option, the product or the defective part. This warranty does not extend to repairs, adjustments, or replacement of a Hunter product or part that results from misuse, negligence, alteration, modification, tampering, or improper installation and/or maintenance of the product. This warranty extends only to the original installer of the Hunter product.

USA

If the controller display shows a station running, flashing sprinkler icon (

USA

The Pro-C controller is supplied with a factory-installed base module for up to 4 stations on the PC-400 and up to 3 stations on the older PC-300. Additional modules may be added in increments of 3 stations (PCM-300) or a single 9-station (PCM-900) to expand the controller’s station capability to 15-16 stations. Additional modules are sold separately. After inserting station modules, pressing the reset button should be done to allow full recognition.  Below you will find information on the compatibility of different modules for both the PC-300 and PC-400 controllers.

USA

Below is a chart indicating the maximum wire runs that can be used when installing Hunter AC solenoids and valves.

USA

The ACC2 Controller can have a maximum of 64 RUN TYPES (events) for each program that may consist of a station, a block (a group of stations), and/or a station delay.

USA

A basic program requires a START TIME, station Run Time, and Water Days to operate automatically. This is where basic automatic irrigation is set up. There are 32 possible automatic irrigation programs with each operating up to 10 Start Times.

USA

A BLOCK is an electronic group of stations that runs at the same time, for the same run time, within a program (Blocks replace “SSGs” in original ACC).

USA

The ACC2 controller allows up to six Pump and/or Master Valve outputs to be assigned in the controller. This applies to the decoder and conventional models. In this article, the following topics are covered:

USA

A new controller installation will begin with at least one or two ATTENTION messages, because the controller has experienced a "power outage" in shipping, and might be discovering new modules. This is normal. Messages on the screen do not interfere with normal irrigation.

When power is first turned on (either with the power switch, or closing one of the slide locks), the Hunter logo screen appears, and the controller begins searching for any irrigation events it may have missed during a power outage.