Use the dial to go to Settings, Networking. Verify the address of the controller by viewing Network Info screen.

  1. Press soft key for Wi-Fi Setup.
  2. Check the box for Direct Connect.
  3. Open mobile device settings for Wi-Fi and search for HunterACC-xxxx (where –xxxx is the unique four digit number shown at Network Info), and connect.

 

;
 

USA

The standard MP Rotators have a matched precipitation rate of approximately 0.4 in/hr. This means any standard MP Rotator at any arc or radius can be placed on the same zone. The MP800SR can be configured to work well in head-to-head coverage in either square or triangular layouts. When square spacing is used, the resulting precipitation rate will be approximately 0.8 in/hr. Since this precipitation rate differs from the standard line of MP Rotators, you should zone the MP800 Series separately to maintain matched precipitation within each zone.

USA

It is important to understand that Solar Sync provides a global seasonal adjustment to the controller. This means that all station run times will be modified by the seasonal adjust percentage shown. When programming the controller, the run times should be entered that represent peak season watering schedules. If the Solar Sync is adjusting to the appropriate seasonal adjust value but the run time for a particular station appears to be too long or short, adjust the station run time in the controller programming.

USA

The table below will assist you in identifying the type of region you live in. There are four basic ET regions, each with descriptions of the region, along with typical ET and temperature characteristics. It is recommended that, if possible, the region be chosen based upon average July ET or peak summer ET.

USA

ACC2 can be updated whenever a new version of the operating system or any of the internal modules is released. These updates are available here at the bottom of this article in the resources section. It is always advisable to stay current with controller updates.

Note:  Do not turn off power to the controller or facepack once the update has started. Damage may result.​

USA

If your sensor is not turning controller back on after a rain event, you may have debris in the spindle of the rain sensor.  Remove the spindle assembly to check for debris or damage to the disks.

 

USA

The base model of HCC is supplied with an ICM-800 station output module. The capacity of the controller is increased when new station modules are installed and recognized.

Standard ICM station modules are available in 4, 8, and 22 station sizes (ICM-400, ICM-800, ICM-2200). These may be added at any time after initial installation. 

Note: The ICM-2200 (22 Station module) should always  be installed in the last two module slots to make it compatible.

USA

All Hunter Industries Anti-Siphon Valves should be installed above ground and at least 6 to 12 inches above the highest sprinkler to prevent back pressure or drainage. Installations at any height lower than this may result in unsafe backflow condition. Consult your local codes to verify this height for your specific area. Do not install any other shut-off valves between the anti-siphon valve and the sprinkler heads.

USA
  1. Yellow power wires to ICC2 AC1 and AC2.
  2. White wires to the sensor terminals. Remove jumper plate from Sensor Terminals.
  3. Gray wires to PROB.

USA

Here are some tips for valve repair.