Before securing the controller to the wall, you must first remove the lower wiring compartment door. The door can easily be removed by following the simple steps below:

  1. Open the external door using the included key if outdoor version model. Indoor version will have no external door.
  2. The lower wiring compartment door can now be removed by pushing downward. See illustration below:

 

 

 

USA

We recommend that a qualified licensed contractor perform this type of winterization method. The blowout method utilizes an air compressor with a cubic foot per minute (CFM) rating of 80-100 for any mainline of 2" or less. The compressor is attached to the mainline via a quick coupler, hose bib, or other type connection, which is located beyond the backflow device. Compressed air should not be blown through any backflow or flow meter device. For additional winterization procedures, we highly recommend contacting the local dealer for the most common local practices.

USA

Hunter warrants the Wireless Rain-Clik (WR-CLIK) for five years. If a defect in a Hunter product is discovered during the applicable warranty period, Hunter will repair or replace, at its option, the product or the defective part. This warranty does not extend to repairs, adjustments, or replacement of a Hunter product or part that results from misuse, negligence, alteration, modification, tampering, or improper installation and/or maintenance of the product. This warranty extends only to the original installer of the Hunter product.

USA

If the controller display shows a station running, flashing sprinkler icon (

USA

The Pro-C controller is supplied with a factory-installed base module for up to 4 stations on the PC-400 and up to 3 stations on the older PC-300. Additional modules may be added in increments of 3 stations (PCM-300) or a single 9-station (PCM-900) to expand the controller’s station capability to 15-16 stations. Additional modules are sold separately. After inserting station modules, pressing the reset button should be done to allow full recognition.  Below you will find information on the compatibility of different modules for both the PC-300 and PC-400 controllers.

USA

Below is a chart indicating the maximum wire runs that can be used when installing Hunter AC solenoids and valves.

USA

The ACC2 controller allows up to six Pump and/or Master Valve outputs to be assigned in the controller. This applies to the decoder and conventional models. In this article, the following topics are covered:

USA

About this event

Advance your education and obtain CEUs by attending this basic training and introduction to two-wire irrigation. Lunch will be provided to all attendees. Space is limited so register now to secure your spot.

The PSR-B was developed to provide a solution for irrigation controller and pump start relays installations that have insufficient power to energize the pump relay. A common cause for this problem is the use of too small a wire size for the distance from controller to the pump start relay.