SRV

Simple, Reliable, and Economical Residential Valve Built To Handle Tough Conditions
Application Residential
Inlet / Outlet 1" (25 mm)
Flow 0.25 to 9.0 m³/hr
Flow 4 to 150 l/min

Models

SRV
SRV
SRV
User installed options

Contact your local distributor for product availability and ordering.

Specifications

Operating Specifications

  • Flow rate: 0.25 to 9 m3/hr; 4 to 150 l/min  
  • Recommended pressure range: 1.5 to 10 bar; 150 to 1000 kPa

Solenoid Specifications

  • 24 VAC solenoid
    • 350 mA inrush, 190mA holding, 60 cycles
    • 370 mA inrush, 210mA holding, 50 cycles

User Installed Options

  • Solenoid conduit cover (P/N 464322)
  • DC latching solenoid (P/N 458200)
  • Accu-Sync pressure regulator

Videos

Troubleshooting a Hunter Valve that is not Opening - Quick Tip

One of the most common reasons for a valve not to open when the controller sends low voltage electricity to the valve is because the exhaust port mig

Cleaning the Diaphragm on a Hunter Valve - Quick Tip

One of the most common reasons for a valve to keep running continuously is the accumulation of debris in the diaphragm, which prevents the valve from

All Product Videos

Features

The SRV was designed to offer dependable performance and affordable pricing for residential applications. Features of the SRV include a durable high-grade PVC globe body plus a rugged diaphragm custom-crafted to withstand the challenge of vigorous day-to-day use. In addition, the SRV boasts a diaphragm support to prevent stress failure, an internal manual bleed to keep the valve box dry, and the heavy-duty Hunter solenoid.

Key Benefits

Application: Residential
Size: 1" (25 mm)
Double-beaded diaphragm seal design for superior leak-free performance
Compatible with Hunter's DC Latching solenoids for use with battery operated controllers
Captive bonnet bolts provide hassle-free valve maintenance
Low flow capability allows use of Hunter’s micro-irrigation products
Encapsulated 24 VAC solenoid with captive plunger for hassle-free service
Temperature rating: 66° C
Warranty period: 2 years

Advanced Features

Avoid sprinkler over-pressure conditions and experience significant water savings with Hunter's Accu Sync pressure regulator. This option is available in adjustable pressure or fixed pressure models.

Charts

 
SRV Pressure Loss in Bar
Flow 1"
m³/hr Globe
0.3 0.08
1.0 0.10
2.5 0.13
3.5 0.13
4.5 0.21
5.5 0.30
7.0 0.43
8.0 0.77
9.0 0.96
 
 
SRV Pressure Loss in KPA
Flow 1"
l/min Globe
4 7.6
20 13
40 13
55 13
75 22
95 35
115 62
130 112
150 139
 

Documents

  • All
  • Manuals
  • Marketing
  • Specifications
  • CAD Details
  • Replacement Parts
Automatic Control Valves - Written Specifications - MasterSpec® thumbnail
Name
Automatic Control Valves - Written Specifications - MasterSpec®
Show all documents