Supervisors - Page 23

The Accu-Sync compares the pressure on the top side of the diaphragm (main water supply pressure) to the downstream pressure.  Pressure is adjusted by the unit forcing the diaphragm downward until the desired pressure is achieved.  The Accu-Sync automatically adjusts to main water supply pressure changes.  To properly set the dynamic pressure (running pressure) on the lateral line with Accu-Sync installed, we recommend doing so using our MP Guage on the last head of the line.  You can purchase a Hunter MP Gauge Assembly (shown below at farthest head) to accurately check the pressure. See i

USA

With the Pro-C controller in production for 17 years, we have continuously made upgrades to accommodate the innovative features.  Below you will find every panel we manufactured for the Pro-C model including the NEW wifi replacement front panel.

USA

Selecting Specific Days of the Week to Water

USA

We would prefer that you use a Hunter valve with a Hunter DC latching solenoid, but we realize that sometimes you may be retrofitting existing systems that have another manufacturer’s valves. We have done testing on the following solenoids and have found these to operate with the Hunter SVC, WVC, NODE and XC Hybrid battery powered controllers. (some of these DC latching solenoids required a reduced system pressure, below 150 PSI (10.34 bars/1034.25 kPa), to ensure proper operation):

USA

The two major components of FLOW OPERATIONS are the Flow Manager and the Flow Monitor features. Checking either will display a reminder of the steps required to set up these features. Press the soft key for Continue to set up the selected function.

USA

The ACC2 Controller can have a maximum of 64 RUN TYPES (events) for each program that may consist of a station, a block (a group of stations), and/or a station delay.

USA

A basic program requires a START TIME, station Run Time, and Water Days to operate automatically. This is where basic automatic irrigation is set up. There are 32 possible automatic irrigation programs with each operating up to 10 Start Times.

USA

FLOW MANAGER runs simultaneous stations to reach a programmable flow rate target. It allows the controller to decide which stations to run, to keep the total flow as close to the pipe design capacity as possible, and shorten the overall watering time. Using this feature does NOT require a flow sensor, but it must have station flow values configured. If flow learning via a sensor is not available, approximate values may be entered manually.

USA

The ACC2 controller allows up to six Pump and/or Master Valve outputs to be assigned in the controller. This applies to the decoder and conventional models. In this article, the following topics are covered:

USA

A new controller installation will begin with at least one or two ATTENTION messages, because the controller has experienced a "power outage" in shipping, and might be discovering new modules. This is normal. Messages on the screen do not interfere with normal irrigation.

When power is first turned on (either with the power switch, or closing one of the slide locks), the Hunter logo screen appears, and the controller begins searching for any irrigation events it may have missed during a power outage.

USA

Pages