Main Display Station runningSprinkler Off DaysProgram IndicatorsWater Days SymbolSolar Sync SymbolDays of the WeekSeason Adjust %Time mode (AM/PM/24)Rain Sensor Active
Basic Programming
-
Setting Current Date and Time
Turn the dial to the DATE/TIME position. The current year will be flashing. Use the and buttons to change the year. Push the button to proceed to setting the month.
-
Setting Program Start Times
Turn the dial to the START TIMES position. Press the button to select A, B, C or D. Use the and buttons to change the start time. The start time advances in 15-minute
-
Setting Station Run Times
Turn the dial to the RUN TIMES position. Use the button to select program (A, B, C, or D). Use the and buttons to change the station run time on the display. You may
-
Cycle and Soak
The Cycle and Soak feature allows you to split a station’s run time into more usable, shorter watering durations. This feature is useful when applying water to slopes and tight
-
Total Runtime Calculator
Turn the dial to RUN TIMES. Press to view total time for all stations in program. Press to see total times for other programs.
-
Seasonal Adjustment
Seasonal Adjust is used to make global run time changes without re-programming the entire controller. This feature is perfect for making small changes that are necessary as the
-
Set Pump/Master Valve
The Pump/Master Valve start can be set ON or OFF by station, regardless of which program the station is assigned. The default is for all stations to have the Pump/Master Valve
-
Solar Sync
Sets up and adjusts optional Hunter Solar Sync sensor. Turn the dial to the SOLAR SYNC positionPress or to select Region , 1-4 (see Solar Sync support).Press or to increase
Sensors
-
Sensor Wiring Update
ICC2 Controllers with manufactured date codes MAY 2024 and newer include updated sensor inputs. These changes are also denoted by a blue sticker on the back of the facepack. The
-
Flow Sensor Wiring
The ICC2 Controller is designed to operate primarily with the Hunter HFS Flow Sensor or the HC Flow Meter. To use the functionality, the controller must have one of three
Flow
Manual Operation
-
Manual Station
Turn dial to MANUAL position. Press to select station. Use or to set manual run time. Turn dial to RUN position to begin immediately. NOTE: The Manual
-
Manual Program
With the dial in the Run position, press and hold the ► button for two seconds and release. This manual one touch start option automatically defaults to program A. You
Troubleshooting
-
Test Stations
Runs all stations for a test run time. Press and hold for 3 seconds. Station 1 appears. Press or to enter run time. Wait 2 seconds, each station will run for test
-
Quick Check
Checks all stations for wiring short circuits, commonly caused by faulty solenoids or when a bare common wire touches a bare station control wire. Press , , , at the
-
Reset
Open inner door (control panel).Press RESET button on back of door. Controller restarts. Controller Total Reset (Erase All)Open inner door (control panel).Press and hold button
-
Troubleshooting Guide
Display Possible Cause Solutions DISPLAY SHOWS "ERR" WITH NUMBER Short in field wiring, or bad
-
Hidden and Advanced Features
Feature Where Found Description PROGRAMMABLE SENSOR OVERRIDE Hold and turn to START TIMES