Welcome Page Body
Welcome to the Soil-Clik support section. The Soil-Clik measures moisture in the soil and stops watering once soil reaches desired moisture level. In this section you will find instructions on connecting, installing, programing and troubleshooting the Soil-Clik sensor.
Section Menu
Probe Installation
-
Specifications
Soil-Clik is a soil moisture system that prevents overwatering when the soil is wet. Soil-Clik is designed for use with Hunter controllers that have normally-closed smart sensor
-
Choosing the Probe Location
The moisture sensing Soil-Clik probe must be installed within 1000 ft (300 m) of the Soil-Clik module, using 18 AWG (1 mm2) Direct Burial (UF) wire. Choosing the Zone Install
-
Connecting the Probe to the Module
Use only 18 AWG (1 mm2) or larger direct burial rated wire, up to 1000 ft (300 m) from the module. Note: Avoid high voltage lines or other sources of electrical interference
Connecting Module
-
Module Location
The Soil-Clik module is designed for outdoor installation when necessary. However, electronics will benefit from a protected location when practical. Mount within 6 ft (2 m) of
-
Wire Overview
Gray Wires: Connection to Soil-Clik Probe. Yellow Wires: Soil-Clik Module power, requires 24 V AC power (100 mA, max). White Wires: Module output, to Hunter controller sensor
-
P2C
A Hunter Soil Clik sensor or other micro-switch-type weather sensors can be connected to the P2C® Controller. The purpose of this sensor is to stop automatic watering when weather
-
X-Core®
Yellow power wires to X-Core 24 VAC terminals. White wires to Sensor (SEN), or common interrupt. Gray wires to PROB.
-
Pro-C®
Yellow power wires to Pro-C AC1 and AC2. White wires to Sensor or common interrupt. Remove jumper plate from Sensor Terminals. Gray wires to PROB.
-
I-Core®
Yellow power wires to I-Core AC1 and AC2. White wires to S1, S2 or S3 terminals. Remove jumper wire from selected Sensor Terminal. Gray wires to PROB.
-
ACC
Yellow power wires to 24 VAC terminal and Com terminal. White wires to any unused sensor S1 through S4. Gray wires to PROB.
-
ICC2
Yellow power wires to ICC2 AC1 and AC2. White wires to the sensor terminals. Remove jumper plate from Sensor Terminals. Gray wires to PROB.
-
Common Interrupt
Common Interrupt (most AC-powered controllers) Connect Yellow power wires to 24 VAC power in the controller. Cut field common wire(s), and splice one Soil-Clik White wire to
-
Using Soil-Clik with Solar Sync®
When paired together, the Hunter Solar Sync and Soil-Clik make the ultimate smart irrigation solution for your sprinkler system. Solar Sync adjusts run times for weather
Programming
-
LCD Screen Callouts
Soil-Clik is used to set a desired moisture level. The level may be changed with the + and - buttons. When the desired moisture has been reached, Soil-Clik will interrupt
-
Operation
The bar steps in the display represent centibars of soil water tension on a scale of 10 to 100. High numbers indicate dry soil, or soil from which it is very difficult for plants
Troubleshooting
-
Troubleshooting
Problem Plants are too dry. Cause Moisture level setting too low. Sensor in wrong location.