- Remove the sensor jumper across the two SEN terminals in the controller.
- Attach the two yellow wires to the 24 VAC terminals.
- Attach the blue wire to one SEN terminal and the white wire to the other SEN or SEN COM terminal.
NOTE: Additional setup steps required for Hydrawise, ACC, and ACC2 Controllers.
Hydrawise Controllers: Complete the installation by configuring the sensor in your Hydrawise account.
ACC Controllers: Use features at the “Set Sensor Operation” dial position on ACC to complete the setup.
ACC2 Controllers: Use “Devices and Sensor Response” options on ACC2 to complete the setup.
Wiring the Receiver to Other Controllers
Wiring the Receiver to Other Controllers: Normally Closed Sensor Applications
- Attach the two yellow wires to the 24 VAC terminals.
- Attach the blue and white wires to the sensor terminals (if available) or in-line with the valve common wire.
Wiring the Receiver to Other Controllers: Normally Open Sensor Applications
- Attach the two yellow wires to the 24 VAC terminals.
- Attach the orange and white wires to the sensor input.