Wireless Mini-Clik Sensor - Wiring

  1. Remove the sensor jumper across the two SEN terminals in the controller.
  2. Attach the two yellow wires to the 24 VAC terminals.
  3. Attach the blue wire to one SEN terminal and the white wire to the other SEN or SEN COM terminal.
 
NOTE: Additional setup steps required for Hydrawise, ACC, and ACC2 Controllers.
Hydrawise Controllers: Complete the installation by configuring the sensor in your Hydrawise account.
ACC Controllers: Use features at the “Set Sensor Operation” dial position on ACC to complete the setup.
ACC2 Controllers: Use “Devices and Sensor Response” options on ACC2 to complete the setup.
 

P2C Sensor Wiring

Wiring the Receiver to Other Controllers

Wiring the Receiver to Other Controllers: Normally Closed Sensor Applications

  1. Attach the two yellow wires to the 24 VAC terminals.
  2. Attach the blue and white wires to the sensor terminals (if available) or in-line with the valve common wire.

Wiring the Receiver to Other Controllers: Normally Open Sensor Applications

  1. Attach the two yellow wires to the 24 VAC terminals.
  2. Attach the orange and white wires to the sensor input.