Feature | Issue | Description |
---|---|---|
Display Shows No SS | A Solar Sync sensor is no longer detected. | This message can appear if the Solar Sync was removed or there is a wiring issue. If the sensor was removed, press the reset button on the back of the panel to clear. |
Display shows ERR with number | Short in field wiring or bad solenoid | Check field wiring and valve solenoid. Press any button to clear ERR message. |
Display shows P ERR | Short in Pump/Master Valve wiring or solenoid | Check wiring and solenoid at P/MV. Check specifications for Pump Start Relay. |
Display shows SP ERR | SmartPort error; electrical noise is present near connection to remote or other SmartPort device | Move connections away from sources of electrical noise. |
Display shows “No AC” | There is no AC power to the controller | Check fuse/breaker and incoming power supply to controller. |
Display shows watering, but no watering is occurring | Problem in field wiring; problem with solenoids; no water pressure to the system | Check field wiring (voltmeter). Check valve solenoid(s). Verify water source is open. |
Rain sensor does not stop irrigation | Jumper wire is not removed; sensor switch in BYPASS position | Remove jumper wire on SEN-2 terminals. Set sensor switch to Active position. |
Controller seems to water continuously | Too many start times | One Start Time operates all stations in a program. Remove unnecessary start times. |