P2C - Troubleshooting Guide

FeatureIssueDescription
Display Shows No SSA Solar Sync sensor is no longer detected.This message can appear if the Solar Sync was removed or there is a wiring issue. If the sensor was removed, press the reset button on the back of the panel to clear.
Display shows
ERR with number
Short in field wiring or bad solenoidCheck field wiring and valve solenoid. Press any button to clear ERR message.
Display shows
P ERR
Short in Pump/Master Valve wiring or
solenoid
Check wiring and solenoid at P/MV. Check specifications for Pump Start Relay.
Display shows
SP ERR
SmartPort error; electrical noise is
present near connection to remote or
other SmartPort device
Move connections away from sources of electrical noise.
Display shows
“No AC”
There is no AC power to the controllerCheck fuse/breaker and incoming power supply to controller.
Display shows
watering, but
no watering is
occurring
Problem in field wiring; problem
with solenoids; no water pressure
to the system
Check field wiring (voltmeter). Check valve solenoid(s). Verify water source is open.
Rain sensor does
not stop irrigation
Jumper wire is not removed; sensor
switch in BYPASS position
Remove jumper wire on SEN-2 terminals. Set sensor switch to Active position.
Controller
seems to water
continuously
Too many start timesOne Start Time operates all stations in a program. Remove unnecessary start times.

 

Still need help? We're here.

Tell us what you need support with and we'll find the best solution for you.