P2C - Specifications

Operating Specifications

  • Station Count: Conventional wiring from 4 to 23 stations,two-wire EZ Decoder System option up to 32 stations.
  • Station Run Time: 1 minute to 6 hours (optional Seconds Mode)
  • Start Times: 4 individual starts per program, three programs available (A, B, C)
  • Watering Schedule: 7-day calendar, interval watering up to a 31-day interval or true odd or even day programming


Electrical Specifications

  • Transformer Input: 120 VAC, 60 Hz (230 VAC, 50/60 Hz for international use)
  • Transformer Output: 24 VAC, 1 A
  • Station Output: 24 VAC, 0.56 A per station
  • P/MV Output: 24 VAC, 0.28 A
  • Maximum Output: 24 VAC, 0.84 A (includes Master Valve Circuit)
  • Battery: 9 V alkaline battery (not included) used only for non-AC programming of the control panel
  • Battery, front panel, internal CR2032 lithium for real-time clock


Cabinet Dimensions

  • Height: 9" (23 cm)
  • Width: 10" (21.5 cm)
  • Depth: 41/2" (10.9 cm)
  • Cabinet is NEMA 3R, IP44 rated


Default Settings

  • All stations are set to zero run time. This controller has a non-volatile memory that retains all entered program data, even during power outages, without need for a battery.

Still need help? We're here.

Tell us what you need support with and we'll find the best solution for you.

Contact Support