ACC2 - Station Limits

STATION LIMITS will allow you to set how many stations can run at once.

  • Stack or Overlap means that each program can be manually set to overlap with other programs or be required to stack. Programs that are set to stack can only run by themselves with no other interference.
  • SmartStack specifies a maximum number of programs that are allowed to overlap across the whole controller.
  • Maximum Simultaneous Stations are the total number of simultaneous stations that can occur for any reason in the entire controller. This is mainly for use with the Flow Manager but applies to all situations.

If Flow Manager is enabled, the display will also show Program Limits. This sets the max number of stations that can run within any one program. This might be used to force irrigation to be spread over a larger number of programs when Flow Manager is scheduling stations on to reach a flow rate target.

Decoder Controller Tip: ACC2 Decoder can operate up to 30 simultaneous stations per controller, but only 20 per decoder output module.

1

Select the lower right soft key to view the MAIN MENU.

2

Turn the scroll wheel to the right to view the STATIONS menu. Press the scroll wheel to select. Turn the scroll wheel to the right to view STATION LIMITS. Press the scroll wheel to select.

3

Turn the scroll wheel to the right to select a PROGRAM STACKING MODE. Press the scroll wheel to select. 

4

Turn the scroll wheel to the right to select the CONTROLLER MAXIMUM STATIONS that will be allowed to run at once for the entire controller. Press the scroll wheel to select. Select a number. Press the scroll wheel to select. Push the HOME button when completed.

5

Turn the scroll wheel to the right to select the PROGRAM MAXIMUM STATIONS that will be allowed to run at once for each program. Press the scroll wheel to select. Select a number. Press the scroll wheel to select.