ACC2 - Program Rules

Program Rules customizes each program for special purposes.

 

Ignore Calendar Days Off

Check the box if the program should be allowed to run on Calendar Days Off that apply to other programs.

 

No Water Window (Start and End)

Enter start and end times for the portion of the day during which automatic irrigation is never allowed. Automatic programs will never be allowed to run during this period, although Manual operations will be allowed. If a program is suspended by a No Water Window, it will be logged as an alarm, for corrective action.

 

Station Delay (Delay Between Stations)

Sets an interval between each station in a program. This can be used for slow-closing valves, recharging pressure tanks, etc. During the delay, the P/MV output will continue running for 15 seconds, unless this is adjusted in the Devices, P/MV Operation screen.