Support
ACC2 Support

ACC2 Decoder - SOS

SOS (Status Output Station)

An SOS is a dedicated station output that is only used with Conditional Response. The purpose of the SOS is to trigger an external light or other device when the controller is in an alarmed state, so that field personnel can be notified of an alarm without having to open the controller door.

An SOS requires a dedicated station number to operate (any station number may be used). The station will turn on whenever the Conditional Response condition is in effect.

Der Stationsausgang kann genutzt werden, um eine 24VAC Signallampe, die in einer Kabelkanalöffnung installiert ist, direkt mit Strom zu versorgen oder um ein Relais zu einem anderen Zweck zu aktivieren.

 

Setup an SOS Station

In the Conditional Response screen, set an "If" condition first, set to Any Alarm or Critical Alarms. Use the "Then" soft key to select a "Start SOS Output" Type.

Wählen Sie unter „Auswahl“ die ungenutzte Station, die Sie als SOS Station festlegen möchten.

  • Diese Station darf nicht für Beregnungsprogramme aktiviert sein.
  • Es kann nur eine SOS Station pro Steuergerät verwendet werden.
  • Alle weiteren SOS Bedingungen sollten für die selbe SOS Stationsnummer ausgewählt werden.
  • Der SOS Stationsausgang wird direkt mit der externen Lampe oder einem anderen 24V Gerät verbunden.
  • In Decoder Controllers, the SOS must be operated by a decoder station. We recommend programming and placing a single station ICD-100 in the controller cabinet for this purpose.

 

Rate this Article: 
0

Was this article helpful? Ja | No